TC1796
System Units (Vol. 1 of 2)
System Control Unit
User’s Manual
5-47
V2.0, 2007-07
SCU, V2.0
SCU_TCLR1
SCU Temperature Compensation 1 Level Register
(F000005C
H
)
Reset Value: 02FF FFFF
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
THCOUNT
THMAX1
rh
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
THMED1
THMIN1
rw
rw
Field
Bits
Type Description
THMIN1
[7:0]
rw
Minimum Threshold for Temp. Compensation 1
Driver level = Low or Min
THMED1
[15:8]
rw
Medium Threshold for Temp. Compensation 1
Driver level = High or Low
THMAX1
[23:16] rw
Maximum Threshold for Temp. Compensation 1
Driver level = Max or High
THCOUNT
[31:24] rh
Threshold Counter
Returns the actual count value of the counter that
counts the
f
POSC
clock pulses. THCOUNT is only
updated when temperature compensation is enabled
(TCE0 or TCE1 or both set).