TC1796
Peripheral Units (Vol. 2 of 2)
Asynchronous/Synchronous Serial Interface (ASC)
User’s Manual
19-22
V2.0, 2007-07
ASC, V2.0
The serial operating modes of the ASC module are controlled by its Control Register
CON. This register contains control bits for mode and error check selection, and status
flags for error identification.
CON
Control Register
(10
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R
LB BRS ODD FDE OE
FE
PE OEN FEN PEN REN STP
M
rw
rw
rw
rw
rw
rwh rwh rwh
rw
rw
rw
rwh
rw
rw
Field
Bits
Type Description
M
[2:0]
rw
Mode Selection
000
B
8-bit data
Synchronous Mode
001
B
8-bit data
Asynchronous Mode
010
B
Reserved. Do not use this combination.
011
B
7-bit data + parity
Asynchronous Mode
100
B
9-bit data
Asynchronous Mode
101
B
8-bit data + wake up bit Asynchronous Mode
110
B
Reserved. Do not use this combination.
111
B
8-bit data + parity
Asynchronous Mode
STP
3
rw
Number of Stop Bit Selection
0
B
One stop bit
1
B
Two stop bits
REN
4
rwh
Receiver Enable Control
0
B
Receiver disabled
1
B
Receiver enabled
Bit is cleared by hardware after reception of a byte in
Synchronous Mode.
PEN
5
rw
Parity Check Enable (asynchronous modes only)
0
B
Ignore parity
1
B
Check parity