TC1796
Peripheral Units (Vol. 2 of 2)
Micro Link Interface (MLI)
User’s Manual
23-129
V2.0, 2007-07
MLI, V2.0
Combined with the baud rate as derived in the MLI module (see
) and the MLIx_FDR fractional divider setup, the resulting MLI baud rate is
defined by:
(23.4)
(23.5)
applies to normal divider mode of the fractional divider
(FDR.DM = 01
B
).
applies to fractional divider mode (FDR.DM = 10
B
).
After a reset operation, both MLI modules are enabled in normal divider mode. According
the MLIx_FDR register’s reset value of 03FF 43FF
H
, the selected baud rate is
f
DMA
/2.
Note that the DMA controller is also enabled after a reset operation with clock
f
DMA
=
f
SYS
.
The receiver baud rate is defined by the following formula.
(23.6)
Baud rate
MLIx
f
DMA
2
-----------------
1
n
---
×
with n = 1024 - FDR.STEP
=
Baud rate
MLIx
f
DMA
2
-----------------
n
1024
-------------
×
with n = 0-1023
=
Baud rate
RL CKm ax
f
M LI
=