MLI, V2.0
The Transmitter Pipe x Status Registers TPxSTATR contain pipe-specific status
information related to address optimization and prediction, data width for transmit data,
and Remote Window size.
TPxSTATR (x = 0-3)
Transmitter Pipe x Status Register
(18
H
+4
H
*x)
Reset Value: 0000 0000
H
31
17 16 15
6 5 4 3
0
0
O
P
AP
DW
BS
r
rh
rh
rh
rh
Field
Bits
Type Description
BS
[3:0]
rh
Buffer Size
This bit field indicates the coded buffer size of the pipe x
Remote Window in the receiving controller. BS further
determines how many address offset bits are
transmitted in a Write Offset and Data Frame or in a
Discrete Read Frame. When register TPxBAR is written
for generation of a Copy Base Address Frame, BS is
updated by the Copy Base Address Frame (see
).
0000
B
1-bit offset address of Remote Window
0001
B
2-bit offset address of Remote Window
0010
B
3-bit offset address of Remote Window
…
B
…
1110
B
15-bit offset address of Remote Window
1111
B
16-bit offset address of Remote Window
DW
[5:4]
rh
Data Width
This bit field indicates the data width that has been
detected for a read or write access of a bus master to a
Transfer Window of pipe x (see
).
00
B
8-bit data width detected
01
B
16-bit data width detected
10
B
32-bit data width detected
11
B
Reserved