background image

UA-Hub

DIN Rail

Self-Tapping Screws 

(Qty. 2)

Screw Anchors 

(Qty. 2)

Package Contents

Note:

 Each UniFi Access component and all third-party accessories are

sold separately.

Installation Requirements

Phillips screwdriver
Ethernet cables, CAT5e or better
Copper wire, 18 AWG to 22 AWG
Drill Kit
DIN Rail
Wire Ferrule Terminal (Recommended)

Sample Wiring Topology

UA-Hub Quick Start Guide

Summary of Contents for UA-Hub

Page 1: ...ch UniFi Access component and all third party accessories are sold separately Installation Requirements Phillips screwdriver Ethernet cables CAT5e or better Copper wire 18 AWG to 22 AWG Drill Kit DIN...

Page 2: ...Door Position Switch Externally Powered Door Opener Magnetic Lock Hardware Overview UA Hub Quick Start Guide...

Page 3: ...ady Blue Adopted device is ready Steady White Pending adoption Alternating White Blue Upgrading firmware Off Not connected or no data link Steady Blue Connected and data link on Off Not connected Stea...

Page 4: ...utput relay with 12VDC Off Not connected Steady Blue Effectively connected Wires are properly connected to both relays in any of the following sets NC COM NO COM Default I O State Matrix LOCK Dry NO C...

Page 5: ...ed Setup Connect AUX POWERED to siren 12V 0 33A 4W for door position warning Note Specific behaviors can be further configured in UniFi Access Controller UA Hub Wiring Connecting the UA Hub to LAN Ens...

Page 6: ...n the lock 2 Connect the Lock Powered COM port on the UA Hub to the on the lock Fail safe lock in this diagram refers to magnetic lock or electric bolt Connecting a Fail Safe Lock with an External Pow...

Page 7: ...REL REX and REN all work the same way with push buttons Connecting a Motion Sensor 1 Connect NO on the motion sensor to REX on the UA Hub 2 Connect COM on the motion sensor to REX on the UA Hub 3 Conn...

Page 8: ...Siren 1 Connect AUX Powered NO on the UA Hub to the on the siren 2 Connect AUX Powered COM on the UA Hub to the on the siren Note AUX powered output is 12VDC up to 0 33A The diagram below is an exampl...

Page 9: ...on the UA Hub 2 Connect COM on the door position switch to the DPS on the UA Hub Connecting an Automatic Door Opener with an External Power Supply Please consult the manual for your specific automatic...

Page 10: ...wer Supply Connect the Lock Powered NO and COM ports on the UA Hub to the NO and COM ports on the fail secure lock respectively Fail secure lock in this diagram refers to electric strike Connecting Wi...

Page 11: ...3 Hardware Installation DIN Rail UA Hub Quick Start Guide...

Page 12: ...Peripherals Sample UniFi Access Diagram Note The UA Hub also features an additional PoE port for the UVC G3 FLEX camera optional UA Hub Quick Start Guide...

Page 13: ...ompanied by their own external power or power adapter Powered locks receive 12VDC power from the UA Hub UniFi Access Controller Setup UniFi Access on your UDM Pro Specifications UA Hub Dimensions 190...

Page 14: ...to 152 5 m 500 ft Lock Relay Output Belden 8750 18 AWG up to 152 5 m 500 ft Auxiliary Relay Output Belden 8750 18 AWG up to 152 5 m 500 ft Wiring Gauge Requirements AWG Total Length to Device Output L...

Page 15: ...uthority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This de...

Page 16: ...duct represents the product is in compliance with all directives that are applicable to it WEEE Compliance Statement Declaration of Conformity Online Resources 2021 Ubiquiti Inc All rights reserved UA...

Reviews: