![Ubiquiti UA-Hub Quick Start Manual Download Page 14](http://html1.mh-extra.com/html/ubiquiti/ua-hub/ua-hub_quick-start-manual_3153220014.webp)
UA-Hub
Powered Relay
Lock
Output 12VDC, up to 1A
Aux
Output 12VDC, up to 0.33A
Line
Output 12VDC, up to 0.33A
LEDs
(1) System, (3) PoE Out, (4) Input
(2) Output Relays, (1) 12VDC Out
Buttons
Terminal Blocks, Reset
Operating Humidity
5 to 90% Non-Condensing
Operating Temperature
0 to 40° C (32 to 104° F)
Certifications
CE, FCC, IC
Specifications for Recommended Wiring
Typical Installation (Shielded)
DC Power Input
Belden 8750 18 AWG 2 Conductor (30.5 m / 100 ft)
Door Position Switch
Belden 8750 18 AWG 2 conductor (152.5 m / 500 ft)
Request to Exit
Belden 8750 18 AWG (up to 152.5 m / 500 ft)
Lock Relay Output
Belden 8750 18 AWG (up to 152.5 m / 500 ft)
Auxiliary Relay Output
Belden 8750 18 AWG (up to 152.5 m / 500 ft)
Wiring Gauge Requirements (AWG)*
Total Length to Device
Output Load Current @ 12VDC
100mA
250mA
500mA
1A
6.1 m (20 ft)
22
22
22
18
15.2 m (50 ft)
22
22
22
18
30.5 m (100 ft)
22
22
18
18
* Use CTE cable connectors that comply with local electrical codes.
Safety Notices
1. Read, follow, and keep these instructions.
2. Heed all warnings.
3. Only use attachments/accessories specified by the manufacturer.
WARNING:
Do not use this product in location that can be submerged by water.
WARNING:
Avoid using this product during an electrical storm. There may be a
remote risk of electric shock from lightning.
UA-Hub Quick Start Guide