TC1796
System Units (Vol. 1 of 2)
System Timer
User’s Manual
15-10
V2.0, 2007-07
STM, V2.0
The STM Module Identification Register ID contains read-only information about the
STM module version.
RMC
[10:8]
rw
Clock Divider in Run Mode
000
B
No clock signal
f
STM
generated
001
B
Clock signal
f
STM
=
f
SYS
selected
(default after reset)
010
B
Clock signal
f
STM
/ 2 selected
011
B
Clock signal
f
STM
/ 3 selected
...
B
...
111
B
Clock signal
f
STM
/ 7 selected
Note: This bit field is not affected by a hardware reset
operation (HDRST = 0).
0
[7:6],
[31:11]
r
Reserved
Read as 0; should be written with 0.
STM_ID
STM Module Identification Register
(08
H
)
Reset Value: 0000 C0XX
H
31
16 15
8 7
0
MODNUM
MODTYPE
MODREV
r
r
r
Field
Bits
Type Description
MODREV
[7:0]
r
Module Revision Number
MODREV defines the module revision number. The value
of a module revision starts with 01
H
(first revision).
MODTYPE
[15:8]
r
Module Type
This bit field defines the module as a 32-bit module: C0
H
MODNUM
[31:16] r
Module Number Value
This bit field defines the module identification number for
the STM: 0000
H
Field
Bits
Type Description