WAGO-SPEEDWAY 767 

Manual 

 

 

 

767-4803/000-800  

8DO 24V DC 2.0A IF (8xM8)

 

Digital Output Module 24 V DC / 2.0 A 

 

Version 1.1.0 

  

 

Pos: 3 /Alle Serien (Allgemeine M odul e)/Hinweise zur Dokumentation/Impressum für  Standardhandbücher - allg. Angaben, Anschriften, Tel efonnummer n und E-Mail-Adressen @ 3\mod_1219151118203_21.docx @ 21060 @  @ 1 

 

Summary of Contents for 767-4803/000-800

Page 1: ...0 docx 64941 1 WAGO SPEEDWAY 767 Manual 767 4803 000 800 8DO 24V DC 2 0A IF 8xM8 Digital Output Module 24 V DC 2 0 A Version 1 1 0 Pos 3 Alle Serien Allgemeine M odul e Hinweise zur Dokumentation Impressum für Standardhandbücher allg Angaben Anschriften Tel efonnummer n und E Mail Adressen 3 mod_1219151118203_21 docx 21060 1 ...

Page 2: ...49 0 571 8 87 85 55 E Mail support wago com Every conceivable measure has been taken to ensure the accuracy and completeness of this documentation However as errors can never be fully excluded we always appreciate any information or suggestions for improving the documentation E Mail documentation wago com We wish to point out that the software and hardware terms as well as the trademarks of compan...

Page 3: ...3 2 Marking Possibilities and Fastening 17 3 3 Display Elements 18 3 4 Labeling 19 3 5 Schematic Diagram 21 3 6 Dimensions 22 3 7 Technical Data 23 3 7 1 General Information 23 3 7 2 Supply 23 3 7 3 Communication 23 3 7 4 Outputs 24 3 7 5 Information on Selecting the Actuator 25 3 7 6 Influence of Operating States on Output 25 3 7 7 Configurable Functions 26 3 7 8 Diagnostics 26 3 7 9 Process Imag...

Page 4: ...1 Output Data 59 8 2 Input Data 61 9 Diagnostics 63 9 1 LED Signaling 63 10 Service 66 10 1 Updating the Firmware 66 10 2 Replacing the Module 66 10 2 1 Disconnecting the Cables 66 10 2 2 Removing the Module from Your System 67 10 2 3 Removing the Module from the Carrier Rail 67 10 2 4 Removing the Module from the Profile Adapter 68 10 2 5 Connecting the Module 68 10 3 Disposal 68 11 Use of the In...

Page 5: ...WAGO SPEEDWAY 767 Table of Contents 5 767 4803 000 800 8DO 24V DC 2 0A IF 8xM8 Manual Version 1 1 0 List of Tables 78 Ende der Liste für Textmar ke Verzeichnis_vor ne ...

Page 6: ...d at www wago com There you will find information regarding supply layout etc Pos 11 All e Seri en Allgemei ne Module Hi nweise zur D okumentati on Hinweise Hinweis Dokumentation aufbewahr en 4 mod_1237987339812_21 docx 29026 1 Always retain this documentation This documentation is part of the product Therefore retain the documentation during the entire service life of the product Pass on the docu...

Page 7: ... All e Serien Allgemei ne Module Wichtige Erläuterungen Sicherheits und sonstige Hinweise Vorsicht Vorsicht _War nung vor Personenschäden allgemein_ Erläuterung 13 mod_1343310028762_21 docx 101038 1 Personal Injury Indicates a low risk potentially hazardous situation which if not avoided may result in minor or moderate injury Pos 13 4 5 All e Serien Allgemei ne Module Wichtige Erläuterungen Sicher...

Page 8: ...O 24V DC 2 0A IF 8xM8 Manual Version 1 1 0 Additional Information Refers to additional information which is not an integral part of this documentation e g the Internet Pos 13 5 Dokumentation allgemei n Glieder ungselemente Seitenwechsel 3 mod_1221108045078_0 docx 21810 1 ...

Page 9: ...1 docx 21714 2 1 1 5 Font Conventions Table 2 Font Conventions Font Type Indicates italic Names of paths and data files are marked in italic type e g C Program Files WAGO Software Menu Menu items are marked in bold letters e g Save A greater than sign between two names means the selection of a menu item from a menu e g File New Input Designation of input or optional fields are marked in bold lette...

Page 10: ...ri en Allgemei ne Dokumente Allgemei ne Module Wichtige Erläuterungen Änderungsvor behalt Ü berschrift 3 und Inhalt 3 mod_1221060036484_21 docx 21720 3 1 2 1 1 Subject to Changes WAGO Kontakttechnik GmbH Co KG reserves the right to provide for any alterations or modifications that serve to increase the efficiency of technical progress WAGO Kontakttechnik GmbH Co KG owns all rights arising from the...

Page 11: ...y oriented module Note the Use of the Interference Free Module in Safety Applications chapter Pos 16 9 Serie 767 WAGO SPEED WAY Wichtige Erläuterungen I O M odul Bestimmungsgemäße Verwendung 767 IOs allgemein2 5 mod_1248176511796_21 docx 38751 1 The module may only be operated in combination with components of the WAGO SPEEDWAY 767 Series The module was developed for applications requiring IP 67 N...

Page 12: ...67 Series component and the overall power consumption for all 767 components Neither of these values shall exceed 4 A since an increase in current causes the contacts to overheat and damages the 767 Series components Information regarding the power demand of each 767 Series component can be found in the corresponding data sheet which is available from www wago com Pos 16 17 Serie 767 WAGO SPEED WA...

Page 13: ...tandards for EMC suitable installations For the power supply and for the S BUS use only pre assembled WAGO system cables so the specified characteristics of the technical data can be achieved Pos 16 20 Serie 767 WAGO SPEED WAY Wichtige Erläuter ung en I O Modul Sicher hei tshi nweise 767 xxxx_4 7 mod_1267623157545_21 docx 51662 1 Replace defective or damaged modules e g deformed connections else f...

Page 14: ...our system to protective earth PE and Pos 16 24 Serie 767 WAGO SPEED WAY Wichtige Erläuter ung en I O Modul Hinweise zum Betri eb 767 I O Teil 2 5 mod_1248180225875_21 docx 38755 1 Ensure that the cable routing and the installation of the fieldbus cable S BUS cable supply cable and sensor or actuator cable are correct Pos 16 25 Serie 767 WAGO SPEED WAY Wichtige Erläuter ung en I O Modul Hinweise z...

Page 15: ...d to control solenoid valves gates transmitters relays or other electrical loads The module has many parameterization options that can be carried out via a fieldbus coupler In addition diagnostic messages for individual channels and for the entire module can be parameterized Use a fieldbus or FDT DTM as for example with the WAGOframe to make module settings Detailed information about assignment of...

Page 16: ...on 1 S BUS input M12 plug B coded For transmitting data from previous 767 Series components 2 S BUS output M12 socket B coded For transmitting S BUS data to the next 767 Series components or to the S BUS terminator Pos 18 7 Serie 767 WAGO SPEED WAY Ger ätebeschrei bung Anschl üsse I O Module Legende Anschl uss 767 4xxx DO 8xM 8 5 mod_1248847874578_21 docx 39163 1 3 Digital outputs X1 X8 M8 socket ...

Page 17: ...ry Pos 18 11 Serie 767 WAGO SPEED WAY Gerätebeschr eibung Befestigung I O Module Legende zu Beschriftung und Befestigung 767 xxxx 5 mod_1249475777546_21 docx 40514 1 Table 4 Legend for figure Marking possibilities and fastening Position Description Function 10 Module marker card For identifying the module within a fieldbus node 11 Mounting holes With integrated function earth FE socket for fasteni...

Page 18: ...9190 1 Table 5 Legend for figure Display elements Position LED Color Meaning 15 SB Green red orange S BUS status 16 F Red Diagnostic information Pos 18 16 Serie 767 WAGO SPEED WAY Gerätebeschr eibung Anzeigeel emente I O M odul e Legende zu Anzeigeel emente 767 48xx Pos 17 Status D O 5 mod_1248855317609_21 docx 39200 1 17 0 7 Yellow red Information on outputs Pos 18 17 Serie 767 WAGO SPEED WAY Ger...

Page 19: ...Labeling exemplary Pos 18 19 3 Serie 767 WAGO SPEEDWAY Gerätebeschr eibung Bedr uckung I O M odul e Legende zur Bedr uckung 767 4803 4804 5 mod_1249023593234_21 docx 39620 1 Table 6 Legend for figure Labeling Position Description 30 Manufacturer s mailing address 31 Connection assignment of S BUS 32 Connection assignment of outputs 33 Connection example 34 Connection assignment of supply input 35 ...

Page 20: ... the module Pos 18 20 Serie 767 WAGO SPEED WAY Gerätebeschr eibung Bedr uckung I O M odul e Bedruckung sei tlich Legende 9 mod_1286969974465_21 docx 65601 1 Table 7 Description of manufacturing number Abbreviation Description WW Week of production JJ Year of production FW Firmware release index When updating the firmware please note that the firmware release index may not be conformed to the print...

Page 21: ...iew of the power supply and principle of operation of the power supply connections as well as the digital outputs of the modules see also chapters Connecting the Supply Cable and Connecting the Actuator Cable Please note that the common power supply of the actuators is distributed to all module connections Pin 1 each Pos 18 24 Serie 767 WAGO SPEED WAY Gerätebeschr eibung Schematische Schaltbilder ...

Page 22: ... Abmessungen Ü berschrift 2 5 mod_1248869612468_21 docx 39441 2 1 3 6 Dimensions Pos 18 27 Serie 767 WAGO SPEED WAY Gerätebeschr eibung Abmessungen I O M odule Abmessungen 767 xxxx_IO_8xM 8 Bild 5 mod_1248872498546_21 docx 39493 1 Figure 7 Dimensions of the module in millimeters exemplary Pos 18 28 D okumentati on allgemei n Gli ederungsel emente Seitenwechsel 3 mod_1221108045078_0 docx 21810 1 ...

Page 23: ... in this application Pos 18 31 Serie 767 WAGO SPEED WAY Gerätebeschr eibung Technische Daten I O M odule Digitalausgangsmodule Technische D aten 767 4803 5 mod_1248948138125_21 docx 39560 33333333333 1 3 7 1 General Information Table 8 Technical Data General Information Width 50 mm Height 35 7 mm Lowness 117 mm Weight Approx 277 g 3 7 2 Supply Table 9 Technical data Supply Connection type M12 conn...

Page 24: ... of outputs 8 Connection type M8 connectors 3 poles Wire connection 2 to 3 wire Output voltage UA Output current per channel 2 0 A max 2 4 A short circuit overload proof thermal disconnection Voltage drop against UA at 2 0 A Maximum 0 2 V DC Output current module Maximum 8 A Leakage current in OFF state Typically 780 µA Output circuit High side switching ...

Page 25: ...uctive load approx 20 Hz Resistive load approx 500 Hz Lamp load approx 500 Hz Recommended minimum load 50 mA Parallel connection of 2 outputs For power boost For redundant actuation of a load Type of protective circuit External protection e g recovery diodes Output resistance Maximum 0 1 Ω Wrong diagnostics may occur at high switching frequencies with reduced load 3 7 6 Influence of Operating Stat...

Page 26: ...l data Diagnostics Per channel Actuator short circuit overload Per channel Interruption Wire break Actuator Per channel Overtemperature Per module Undervoltage ULS UA 3 7 9 Process Image Table 16 Technical data Process Image Process data width 1 byte data status 3 7 10 Display Elements Table 17 Technical data Display Elements SB S BUS status LED green red orange F Error status LED red 0 7 Output s...

Page 27: ...ungen cU Lus UL508 3 mod_1224055013140_0 docx 24020 1 CULUS UL508 Pos 18 33 3 3 D okumentati on allgemein Gli ederungsel emente Leerzeil e 3 mod_1224662755687_0 docx 24460 1 Pos 18 33 4 Serie 767 WAGO SPEEDWAY Gerätebeschr eibung Zul assung en Zul assung en I O Modul e 767 xxxx Ex ohne Variantenangabe Ei nlei tung 24 mod_1447686155055_21 docx 195692 1 The following Ex approvals are pending for 767...

Page 28: ...33 1 Ex Directive 94 9 EC Pos 18 35 7 Alle Serien Allgemeine M odul e Nor men und Richtlini en Ex i Nor men Explosionsfähig e Atmosphär e EN 60079 0 14 mod_1360841627885_21 docx 111880 1 Explosive atmosphere EN 60079 0 Devices General requirements Pos 18 35 8 Alle Serien Allgemeine M odul e Nor men und Richtlini en Ex i Nor men Explosionsfähig e Atmosphär e EN 60079 15 13 mod_1351072320086_21 docx...

Page 29: ...nweise 767 xxxx allgemei n_1 5 mod_1249028727125_21 docx 39643 2 1 4 1 Information on Mounting The following information shall always be observed Disconnect the power supply from the system before you start with installation The maximum diameter of the drill hole of the module s mounting holes is not to exceed 4 mm Otherwise a full contact with function earth FE socket of the module not be guarant...

Page 30: ...6523_21 docx 196008 1 Any mounting position is possible Ensure a safe mounting position In explosion hazardous environments no increased mechanical loads must be present at the installation location If shocks are possible a shock protection must be installed between the module and the possible source of the shock Pos 21 6 Dokumentation allgemei n Glieder ungselemente Seitenwechsel 3 mod_1221108045...

Page 31: ...dbus manuals in the Accessories section Select the manual appropriate to the fieldbus you are using Carrier rail adapter including fixing screws and perforated or imperforated carrier rails DIN rail 35 x 7 5 or DIN rail 35 x 15 according to EN 60715 also available from WAGO or Profile adapter including fixing screws Spacer optional Two M4x12 screws are required for direct mounting of the module Th...

Page 32: ...nnect all cable without problems Pos 21 11 Serie 767 WAGO SPEED WAY Wichtige Erläuter ung en Sicherheitshinweise Hinweis Hi nweis 767 xxxx Distanzstück 8 mod_1279025151416_21 docx 59810 1 Direct Mounting We recommend using WAGO spacers for compact direct mounting If these are used the resulting additional distance from the second 767 Series component is to be noted See section Mounting the Module ...

Page 33: ...rrier Rail Adapter to the Module A carrier rail adapter is required to mount the module on carrier rails Screw together the module and carrier rail adapter using the M4 threaded screws provided as shown in the figure below Pos 21 16 Serie 767 WAGO SPEED WAY Monti eren I O M odule Montage auf Tr agschi ene 767 xxxx_8xM 8 Bild 5 mod_1249030505593_21 docx 39750 1 Figure 9 Fastening to the carrier rai...

Page 34: ...connect the power supply from those devices on which you wish to mount the module 2 Set the module onto the edge of the carrier rail 51 with the two notches 50 3 Press the undersurface against the lower carrier rail edge until the latch 52 locks in place Use end stops When mounting the rail vertically or if shock or vibration loading should occur the use of end stops item no 249 116 or 249 117 for...

Page 35: ...e you also have the option to fasten it to a profile rail using the profile adapter and nuts provided that this mounting type is supported by your system You are to supply the necessary nuts Screw together the module and the profile adapter using the M4 threaded screws provided as shown in the following figure Pos 21 22 Serie 767 WAGO SPEED WAY Monti eren I O M odule Montage an einer Pr ofilschien...

Page 36: ...em two nuts are required with one screw each length of screw threads must be compatible with your system 1 Disconnect the power supply from those devices on which you wish to mount the module 2 Insert the two screws into the holes above and beneath the fastened module on the profile adapter 3 Fasten an appropriate nut on each of these screws 4 Insert the profile adapter with the attached module in...

Page 37: ... slot width 3mm into the small opening under the marking strip cover 12 and lever it up 2 Remove the marking strip cover 3 Mark the marking strip with a waterproof pen 4 Reinsert the marking strip cover and press it firmly in place If the module s marker card 10 must be replaced proceed in accordance with the step sequence described previously New module marker cards can be obtained through WAGO P...

Page 38: ... included on the spacer for cable ties 1 Disconnect the power supply from those devices on which you wish to mount the module 2 The spacer can only be inserted into the appropriate openings of the module from the bottom To bind both components place the module on the spacer or push the spacer from the bottom into the module 3 Fasten the attached components on a flat surface by fastening the module...

Page 39: ...y one 767 component connected with a spacer can be attached and screwed on to the preceding component due to the mounting direction The last 767 component is fastened without a spacer Pos 21 33 Serie 767 WAGO SPEED WAY Monti eren I O M odule Montage_DistanzstückTeil 2_767 xxxx_8xM 8 Bild 5 mod_1249281783109_21 docx 39809 1 Figure 14 Attaching another module with a spacer Pos 22 D okumentation allg...

Page 40: ...omponent can be found in the corresponding data sheet which is available from www wago com Pos 23 5 Serie 767 WAGO SPEED WAY Wichtige Erläuterungen Sicherheitshinweise Achtung Achtung Offene Anschlüsse 8 mod_1278308159953_21 docx 58910 1 Exposed connections If connections have not been closed with protective caps liquid or dirt can penetrate the components of the 767 Series module and ruin it Ther...

Page 41: ...ing radiuses of the WAGO system cable For more information see the technical data at www wago com When laying all cable ensure that you do not lay it in shear areas of moving machine parts Observe the correct layout of the potential equalization Pos 23 10 Serie 767 WAGO SPEED WAY Anschluss D aten und Versorgungskabel I O M odule Anschluss_Zubehör allgemein 5 mod_1249287357968_21 docx 39869 2 1 5 2...

Page 42: ...ed for communication between a fieldbus coupler and the connected 767 Series components Requirement A WAGO S BUS cable pre assembled on both ends is readily available to you This is necessary for optimal signal transmission The S BUS terminator is available to you which is necessary for communication The following table outlines the assignment of the S BUS connections Table 19 S BUS connection ass...

Page 43: ...dules have been connected to the fieldbus coupler connect the S BUS cables S1 S2 to the associated IN and OUT connections as shown in the following figure 3 Tighten the plugs and sockets using the knurled head screws 4 Attach the S BUS terminator T to the last I O module as shown in the figure and tighten it Pos 23 13 Serie 767 WAGO SPEED WAY Anschluss D aten und Versorgungskabel I O M odule Ansch...

Page 44: ...ions also from one power supply In addition the supply lines must have the same line resistance same length and cross section to achieve an equal current distribution to the supply connections Table 1 Supply connection assignment Connection Contact Description IN K2 1 24 V DC ULS 2 24 V DC UA 3 0 V ULS 4 0 V UA IN K3 1 24 V DC ULS 2 24 V DC UA 3 0 V ULS 4 0 V UA Pos 23 16 Serie 767 WAGO SPEED WAY ...

Page 45: ...of 2 A for each channel retransmission of the power supply is not possible It has two IN connections as a result of the increased power requirement For subsequent modules the power supply must therefore be newly fed 3 Use the two IN connections K2 K3 to supply power for the 2 A module as shown in the following figure 4 Tighten the plugs and sockets using the knurled head screws 5 Screw a protectiv...

Page 46: ...ing table outlines the assignment of the actuator connections Table 20 Connection assignment of digital outputs Connection Connection diagramm OUT OUT X1 X3 X5 X7 X2 X4 X6 X8 Pos 23 22 Serie 767 WAGO SPEED WAY Wichtige Erläuter ung en Sicherheitshinweise Achtung Achtung Höchste Strombel astbar keit der Vers kontakte Aktor en 8 mod_1278305558285_21 docx 58898 1 The highest current carrying capacity...

Page 47: ...er supply from those devices on which you have mounted the module 2 Insert the actuator cable plug into an output socket 3 of the module and tighten it via knurled head screw 3 Screw a protective cap on all unused ports to ensure that IP67 degree of protection is provided Pos 23 25 Serie 767 WAGO SPEED WAY Anschluss D aten und Versorgungskabel I O M odule Anschlüsse_8xM8_Sensoren Aktoren Bild 5 mo...

Page 48: ...aps which must be ordered separately in order to maintain the IP67 degree of protection See section Accessories of the fieldbus coupler controller manual Pos 27 Serie 767 WAGO SPEED WAY In Betrieb nehmen I O Modul e Inbetriebnahme allgmein 5 mod_1249365805015_21 docx 40130 1 Before starting up the 767 node ensure that the following requirements are met Both 767 Series Fieldbus Coupler and Module 7...

Page 49: ... in a dangerous state and personnel and machines could be at risk Before changing the parameters ensure that the machine components are in a safe and defined state and switch off the higher level controller Also ensure before start up that no personnel remain in the danger area of the machine components For the parameterization of the module an appropriate DTM is available Via this DTM you can par...

Page 50: ...only Writes the modified values to the module Close Online and offline mode Closes the parameterization user interface DTM Apply Offline mode only Applies the entries in the project Please note that the project should also be subsequently saved File Save Help Online and offline mode Opens the online help for an entry that has been previously selected in the DTM e g digital inputs global setting Sh...

Page 51: ...nufacturer Release index FW HW FL FW Actual firmware release index When updating the firmware please note that the firmware release index may not be conformed to the printed firmware release index on the side of the fieldbus coupler HW Hardware release index FL Firmware loader release index Firmware revision General information on the module Order number Description Serial number Date of productio...

Page 52: ...ffer from the actual module Pos 30 7 Serie 767 WAGO SPEED WAY Par ametrieren I O M odule Parametri erung 767 xxxx Di agnoseübersicht_2 7 mod_1265811272140_21 docx 50279 1 Table 23 Diagnostics setup Parameter Description Insert in PI By unselecting the checkbox you specifically suppress evaluation and transmission of individual diagnostics Doing so has no effect on the size of the process image Eve...

Page 53: ... Serie 767 WAGO SPEED WAY Parametrier en I O Module Parametrier ung Kanaldi agnosen Kurzschl uss Überlast Aktor 8 mod_1278414485725_21 docx 59134 1 Table 25 Information about an existing channel diagnostic Channel Diagnostics Diagnostics Description Actuator short circuit overload The module has identified a short circuit or overload on the corresponding channel 1 8 only enabled when the actuator ...

Page 54: ...cx 40292 1 Table 26 Overview of adjustable parameters for the digital outputs Parameter Description Designation Electronic marking field max 40 characters Output value This value is released to the outputs Default setting 0 Process image value This value is released from the process image to the outputs taking into account inversion If manual operation is activated a value entered here is released...

Page 55: ... 1 The output is only switched on again after you confirm the diagnostic message Restart delay actuator Time in 100 ms intervals after which a disabled output is switched on again in case of error You must unselect the checkbox under Restart mode actuator 0 Default setting 10 100 ms 1000 ms Note If you set the time of the Restart delay actuator parameter to 0 ms the I O LED appears yellow instead ...

Page 56: ...scription Simulation diagnostic If the checkbox is selected you can simulate a low voltage diagnostic To generate a low voltage diagnostic one or both of the two checkboxes Low voltage ULS and Low voltage UA must be selected Default setting unselected Low voltage ULS In the case of an undervoltage of the logic and sensor supply ULS or the actuator supply UA the corresponding diagnostic is displaye...

Page 57: ...t be replaced due to a defect you do not need to reconfigure the new I O module The stored parameters are automatically transferred to the new I O module Detailed information on this procedure can be found in the fieldbus coupler manuals in the Parameter Setting via FDT DTM section Pos 30 22 Serie 767 WAGO SPEED WAY Parametrier en I O Module Parametrier ung 767 xxxx Aktualisier ung der Firmwar e 7...

Page 58: ...bus coupler that supports the synchronous diagnostic function e g 767 1101 or 767 2301 Detailed information about enabling the transmission of diagnostic information can be found in the manual for the fieldbus coupler being used see the section about the device description file In addition you can also switch on synchronous diagnostic information in fieldbus couplers that support this function by ...

Page 59: ...short circuit overload on channel 1 confirmed 1B Actuator short circuit overload on channel 2 confirmed 1B Actuator short circuit overload on channel 3 confirmed 1B Actuator short circuit overload on channel 4 conf 1B Actuator short circuit overload on channel 5 confirmed 1B Actuator short circuit overload on channel 6 confirmed 1B Actuator short circuit overload on channel 7 confirmed 1B Actuator...

Page 60: ...n channel 3 confirmed 1B Overtemperature on channel 4 confirmed 1B Overtemperature on channel 5 confirmed 1B Overtemperature on channel 6 confirmed 1B Overtemperature on channel 7confirmed 1B Overtemperature on channel 8 confirmed Byte 4 7 0 Diagnostic confirmation 1B Undervoltage ULS confirmed 1B Undervoltage UA confirmed Pos 37 D okumentation allgemei n Glieder ungselemente Seitenwechsel 3 mod_1...

Page 61: ...oad on channel 3 1B Actuator short circuit overload on channel 4 1B Actuator short circuit overload on channel 5 1B Actuator short circuit overload on channel 6 1B Actuator short circuit overload on channel 7 1B Actuator short circuit overload on channel 8 Byte 1 7 0 Diagnostic message 1B Actuator supply open load on channel 1 1B Actuator supply open load on channel 2 1B Actuator supply open load ...

Page 62: ...0 Byte 3 7 0 Diagnostic message 1B Undervoltage ULS 1B Undervoltage UA Diagnostic messages Normally both Actuator short circuit and Overtemperature diagnostic messages are issued simultaneously Pos 39 D okumentation allgemei n Glieder ungselemente Seitenwechsel 3 mod_1221108045078_0 docx 21810 1 ...

Page 63: ... diagnostics Use the diagnostic overview section Parameterizing Diagnostic Overview to disable specific diagnostics see F and I O LED In this case the corresponding LED is disabled off Pos 42 3 Serie 767 WAGO SPEED WAY Di agnose I O Modul e Betriebsmel dungen 767 xxxx Abbildung 8xM 8 5 mod_1249454303828_21 docx 40393 1 Figure 20 LEDs indicating operational messages exemplary Pos 42 4 Serie 767 WAG...

Page 64: ... Hz The S BUS parameters are being stored by the fieldbus coupler Orange The firmware is being updated All 767 Series components are being updated by the fieldbus coupler within the node Orange flashing 4 Hz The module is attempting to establish communication with the fieldbus coupler Check the power supply to upstream 767 Series component and or check the S BUS cable for damages Pos 42 5 Serie 76...

Page 65: ...n be diagnosed an interruption cannot If the output is switched off only an interruption detection can be diagnosed line break If you set the time of the parameter Restart delay actuator section Parameterizing Parameters of outputs to 0 ms the I O LED appears yellow rather than red in case of a short circuit or overload due to the short restart interval Pos 42 8 Serie 767 WAGO SPEED WAY Di agnose ...

Page 66: ...2 Replacing the Module To replace a module e g to change variants proceed as described follow 10 2 1 Disconnecting the Cables Before removing the connectors clean the module to ensure that no dirt or other material comes in contact with the connections This can lead to damage of the contacts To unplug the cables proceed as follows 1 Disconnect the power supply from those devices on which you have ...

Page 67: ...0 2 3 Removing the Module from the Carrier Rail In order to keep the representation unambiguous the carrier rail adapter in the following figure B C is shown without module If the module is mounted on a carrier rail proceed with the removal as follows 1 Disconnect the power supply from those devices on which you have mounted the module 2 To remove the module press down the release actuator of the ...

Page 68: ...and remove the module from the profile rail of your system 3 Unscrew the screws that connect the module with the profile adapter 10 2 5 Connecting the Module To connect the module proceed as described in Sections 4 through 6 If necessary the parameters of the previous module are transferred to the new module depending on the type of fieldbus coupler being used For more information see section Para...

Page 69: ...satz in sicherheitsg erichteten Anwendung en 767 xxxx_Wichtige Hinweise_2 11 mod_1317280411044_21 docx 80000 2 1 11 1 Important Notes Only use SELV PELV power supplies Only a power supply unit with protective extra low voltage SELV PELV shall be used for the 24V power supply Prevent short circuits to external voltages on the digital outputs A short circuit of a digital output to external voltages ...

Page 70: ... must be tightened at a torque of 0 6 Nm Otherwise the safe shutdown of the I O module by a safety switching device in the case of penetrating pollution cannot be ensured Observe connecting cable specification The values indicated in the specification for the connecting cables regarding the environmental characteristics and mechanical load capacity must never be exceeded Use safety switching devic...

Page 71: ...f error UA and ULS can each be protected using a safety fuse according to EN 60127 2 or electronic fuse e g WAGO 787 861 Safety fuses according to EN 60127 2 must meet the following technical requirements G fuse link e g WAGO Order No 282 122 Rated current 4 A Time lag Surge resistant Large or increased breaking capacity Rated voltage 60 V DC Time current characteristic 275 from rated current corr...

Page 72: ...o EN 60204 1 or EN ISO 13849 2 The shield must have an overlap of at least 85 and be reliably connected to the connector Attach ground shield or use insulation monitoring The connecting lead ground shield and functional grounding connection of the interference free modules must be connected to lines 0 V_ULS and 0 V_UA In addition insulation monitoring according to EN 61557 can also be used See the...

Page 73: ...ou use unshielded connecting cables to supply interference free modules you are required to install the connecting cables according to EN 60204 1 or EN ISO 13849 2 in a cable duct armored conduit or shielded installation space The measures must be suitable to ensure fault exclusion short circuit between any two conductors according to EN 60204 1 or EN ISO 13849 2 The fault exclusion must apply to ...

Page 74: ...g the interference free module in safety related applications you must combine the interference free modules belonging to one safety switching device in a potential group The power supply UA of the interference free module may only be connected to the digital output of a suitable safety switching device 24 V Figure 25 Example structure of potential groups Pos 58 D okumentation allgemei n Glieder u...

Page 75: ...igure 26 Single pin shutdown of the power supply of all digital outputs Figure 27 Two pin shutdown of the power supply of all digital outputs Pos 60 D okumentation allgemei n Glieder ungselemente Seitenwechsel 3 mod_1221108045078_0 docx 21810 1 Safety switch module Safety module Output module Safety components safety input safety output Actuator 1 Actuator 2 Logic Logic safety input Safety switch ...

Page 76: ... diagnostic codes can be generated by the module Table 32 Diagnostics of the module Diagnostic Message Attribute Path Classification C I A Low voltage ULS sensor supply 50 1 128 Diagnostic alarm Low voltage UA actuator supply 50 1 129 Diagnostic alarm Table 33 Diagnostics of the individual channels of the module Diagnostic Message Attribute Path Classification C I A Actuator short circuit overload...

Page 77: ...ttaching another module with a spacer 39 Figure 15 S BUS connected to a fieldbus coupler and modules 43 Figure 16 Supply cable connected to the fieldbus coupler I O module and 2 A module 45 Figure 17 Connectors exemplary 47 Figure 18 Example of an open DTM including parameters 50 Figure 19 Example of the diagnostic overview of a module information may differ from the actual module 52 Figure 20 LED...

Page 78: ...e 13 Technical data Influence of Operating States on Output 25 Table 14 Technical data Configurable Functions 26 Table 15 Technical data Diagnostics 26 Table 16 Technical data Process Image 26 Table 17 Technical data Display Elements 26 Table 18 Technical data Isolation 26 Table 19 S BUS connection assignment 42 Table 20 Connection assignment of digital outputs 46 Table 21 DTM buttons 50 Table 22 ...

Page 79: ...WAGO SPEEDWAY 767 List of Tables 79 767 4803 000 800 8DO 24V DC 2 0A IF 8xM8 Manual Version 1 1 0 Ende der Liste für Textmar ke Verzeichnis_hi nten ...

Page 80: ...ite 2015 9 mod_1285229376516_21 docx 64944 1 WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastraße 27 D 32423 Minden Phone 05 71 8 87 0 Fax 05 71 8 87 1 69 E Mail info wago com Internet http www wago com Ende der Liste für Textmar ke Ei nband_hinten ...

Reviews: