SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
411
2 Parameters
2.2 List of parameters
For bit 00:
Calculation for the constant and linear coefficients of the moment of inertia precontrol is activated. The results are
written to parameters (p5312, p5313, p5314, p5315).
For bit 01:
The moment of inertia precontrol is activated.
The moment of inertia is calculated from the currently measured load torque and the saved coefficients (p5312,
p5313, p5314, p5315).
Description:
Displays the status word for the moment of inertia precontrol.
Dependency:
The function module "Moment of inertia estimator" (r0108.10) must be activated for the "Moment of inertia precontrol"
function.
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: p5310, p5312, p5313, p5314, p5315
Description:
Setting of the linear coefficients for moment of inertia precontrol in the positive direction when the moment of inertia
estimator is active.
The estimated moment of inertia is obtained according to the following formula:
Moment of inertia (J) = linear coefficient (p5312) * load constant coefficient (p5313)
Dependency:
The function module "Moment of inertia estimator" (r0108.10) must be activated for the "Moment of inertia precontrol"
function.
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: p5310, r5311, p5313, p5314, p5315
Description:
Setting of the constant coefficients for moment of inertia precontrol in the positive direction when the moment of
inertia estimator is active.
The estimated moment of inertia is obtained according to the following formula:
Moment of inertia (J) = linear coefficient (p5312) * load constant coefficient (p5313)
r5311[0...n]
Moment of inertia precontrol status word / J_prectrl ZSW
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
New measuring points are available
Yes
No
-
01
New parameters being calculated
Yes
No
-
02
Moment of inertia precontrol active
Yes
No
-
03
Calculation of positive coefficients
completed
Yes
No
-
04
Calculation of negative coefficients
completed
Yes
No
-
05
Results are being written to parameter
Yes
No
-
p5312[0...n]
Moment of inertia precontrol linear positive / J_est lin pos
Access level:
3
Calculated:
p0340 = 1
Data type:
FloatingPoint32
Can be changed:
C(3), U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
-340.28235E36 [s^2]
340.28235E36 [s^2]
0.000000 [s^2]
p5313[0...n]
Moment of inertia precontrol constant positive / J_est const pos
Access level:
3
Calculated:
p0340 = 1
Data type:
FloatingPoint32
Can be changed:
C(3), U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
25_1
Unit selection:
p0100
Func. diagram:
-
Min Max
Factory
setting
-340.28235E36 [kgm²]
340.28235E36 [kgm²]
0.000000 [kgm²]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......