2 Parameters
2.2 List of parameters
Description:
Displays the rated motor stator resistance at rated temperature (total of p0625 and p0627).
Dependency:
Refer to: p0627
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
Description:
Displays the motor rotor resistance at an ambient temperature p0625.
Dependency:
Refer to: p0625
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
Description:
Displays the nominal rotor resistance of the motor at the rated temperature.
The rated temperature is the sum of p0625 and p0628.
Dependency:
Refer to: p0628
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
Description:
Displays the stator leakage inductance of the motor including the motor reactor (p0233).
Description:
Displays the stator longitudinal inductance of the synchronous motor including the motor reactor (p0233).
r0373[0...n]
Motor rated stator resistance / Mot R_stator rated
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
MDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- [ohm]
- [ohm]
- [ohm]
r0374[0...n]
Motor rotor resistance cold / Mot R_r cold
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
MDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- [ohm]
- [ohm]
- [ohm]
r0376[0...n]
Rated motor rotor resistance / Mot rated R_rotor
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
MDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- [ohm]
- [ohm]
- [ohm]
r0377[0...n]
Motor leakage inductance total / Mot L_leak total
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
MDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
r0378[0...n]
Motor stator inductance d axis / Mot L_stator d
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
MDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......