SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
241
2 Parameters
2.2 List of parameters
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Note:
For bit 17:
Displays the enabled status of the rugged model feedback (p1784).
The feedback is used to increase the parameter ruggedness of the motor model and is effective in the operating
range of the two-component closed loop current control.
For bit 18:
Displays the status when enabling the differential current feedback in the current model for operation with encoder.
The function is automatically enabled with p1784 > 0 or p1731 > 0. The feedback is used for a rugged change
between the current model and complete machine model with active rugged model feedback and combination
current.
For bit 19:
Displays the currently active stator circuit feedback in current model operation.
For bit 20:
Displays the currently effective increase of the changeover limits by the value p1749 * p1755.
For bit 21:
For a blocked synchronous motor, the speed ramp-function generator is held in the open-loop speed controlled
operating range if the torque setpoint reaches the torque limit and the speed is less than the threshold value in
p2175.
Description:
Sets the speed to change over the motor model for operation with encoder.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: p1756
Description:
Sets the hysteresis for the changeover speed of the motor model for operation with speed encoder.
04
Encoder operation
Active
Inactive
-
05
Holding angle
Yes
No
-
06
Acceleration criterion
Active
Inactive
-
07
Set angular integrator PMSM
Yes
No
-
08
Stop Kt adaptation PMSM
Yes
No
-
09
PolID active PMSM encoderless
Yes
No
-
10
I injection PMSM
Yes
No
-
11
Speed controller output cannot be set to
zero
Yes
No
-
12
Rs adapt waits
Yes
No
-
13
Motor operation
Yes
No
-
14
Stator frequency sign
Positive
Negative
-
15
Torque sign
Motor mode
Regenerative mode
-
16
Pulse injection active PMSM
Yes
No
-
17
Operation with rugged model feedback
Enabled
Inhibited
-
18
Operation of the current model with current
feedback
Enabled
Inhibited
-
19
Current feedback in the current model
Active
Inactive
-
20
Rugged increase of the changeover limits
Active
Inactive
-
21
Motor blocked (RFG stop) PMSM
No
Yes
-
p1752[0...n]
Motor model changeover speed operation with encoder / MotMod n_chgov enc
Access level:
3
Calculated:
p0340 = 1,3
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
-
Min Max
Factory
setting
0.00 [rpm]
210000.00 [rpm]
210000.00 [rpm]
p1753[0...n]
Motor model changeover speed hysteresis operation with encoder /
MotMod n_chgovHysE
Access level:
3
Calculated:
p0340 = 1,3
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.0 [%]
90.0 [%]
0.0 [%]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......