2 Parameters
2.2 List of parameters
SINAMICS G120D
366
List Manual (LH14), 01/2016, A5E33842313
Description:
Sets the mode to evaluate "external block change".
Value:
0:
External block change via the measuring probe
1:
External block change via BI: p2633
Dependency:
Refer to: p2623, p2633, r2677, r2678
Note:
In the mode "external block change via measuring probe (p2632 = 0), the following applies:
When starting a traversing block with the block change enable CONTINUE_EXTERNAL,
CONTINUE_EXTERNAL_WAIT and CONTINUE_EXTERNAL_ALARM an activated "flying referencing" is
interrupted. After ending the block, "flying referencing" must be re-activated via BI: p2595 = 0/1 signal.
Description:
Sets the signal source for "external block change".
BI: p2633 = 0/1 signal
Dependency:
The evaluation of the signal is only active p2632 = 1.
Refer to: p2623, p2632, p2640, p2641, r2677, r2678
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
A 0/1 edge initiates a flying block change in the subsequent traversing block.
When the external block change is identified, the actual position is saved in r2678.
A traversing task can be influenced using the following signals:
- intermediate stop via BI: p2640.
- reject traversing task via BI: p2641.
Description:
Sets the following error to detect the "fixed stop reached" state (r2526.4).
Dependency:
Refer to: r2526, p2621, r2675
Note:
The state "fixed stop reached" is detected if the following error exceeds the theoretically calculated following error
value by p2634.
Description:
Sets the monitoring window of the actual position after the fixed stop is reached.
Dependency:
Refer to: r2526, r2683
Refer to: F07484
p2632
EPOS external block change evaluation / Ext BlckChg eval
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3615, 3616
Min Max
Factory
setting
0 1 0
p2633
BI: EPOS external block change (0 -> 1) / Ext BlckChg (0->1)
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3615
Min Max
Factory
setting
- - 0
p2634[0...n]
EPOS fixed stop maximum following error / Following err max
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
Unsigned32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
3617, 4025
Min Max
Factory
setting
0 [LU]
2147482647 [LU]
1000 [LU]
p2635
EPOS fixed stop monitoring window / Fixed stop monit
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
Unsigned32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3617, 4025
Min Max
Factory
setting
0 [LU]
2147482647 [LU]
100 [LU]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......