2 Parameters
2.2 List of parameters
SINAMICS G120D
380
List Manual (LH14), 01/2016, A5E33842313
Note:
For bit 02:
The "referencing active" signal is an OR logic operation of "search for reference active" and "flying referencing
active".
For bit 00 ... 07 and 11 ... 14:
These signals are generated in the function module "basic positioner".
For bit 08:
The signal is generated in the "closed-loop position control" function module.
Description:
Displays the corrective value for the position actual value.
Dependency:
Refer to: r2684
Note:
As standard, the following BICO interconnection is established: CI: p2513 = r2685
Using this value, e.g. modulo corrections are carried out.
Description:
Displays the effective torque limiting.
r2686[0]:
Displays the effective upper torque limiting when traversing to fixed stop (referred to CI: p1522, CI: p1523).
r2686[1]:
Displays the effective lower torque limiting when traversing to fixed stop (referred to CI: p1522, CI: p1523).
Index:
[0] = Upper
[1] = Lower
Dependency:
Refer to: p1520, p1521, p1522, p1523, r2676
Note:
As standard, the following BICO interconnections are established:
CI: p1528 = r2686[0]
CI: p1529 = r2686[1]
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Search for reference active
Active
Not active
3612
01
Flying referencing active
Active
Not active
3614
02
Referencing active
Active
Not active
-
03
Printing mark outside outer window
Yes
No
3614
04
Axis accelerating
Yes
No
3635
05
Axis decelerating
Yes
No
3635
06
Jerk limiting active
Yes
No
3635
07
Activate correction
Yes
No
3635
08
Following error in tolerance
Yes
No
4025
09
Modulo correction active
Yes
No
-
10
Target position reached
Yes
No
4020
11
Reference point set
Yes
No
3612,
3614,
3630
12
Acknowledgment traversing block activated Yes
No
3616,
3620
13
STOP cam minus active
Yes
No
3630
14
STOP cam plus active
Yes
No
3630
15
Traversing command active
Yes
No
3635
r2685
CO: EPOS corrective value / Corrective value
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3635
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]
r2686[0...1]
CO: EPOS torque limiting effective / M_limit eff
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3616, 3617
Min Max
Factory
setting
- [%]
- [%]
- [%]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......