2 Parameters
2.2 List of parameters
SINAMICS G120D
406
List Manual (LH14), 01/2016, A5E33842313
Description:
Sets the configuration for the motor temperature sensor.
Dependency:
Refer to: p0601
Notice:
For bit 00:
If the short-circuit monitoring is de-activated, this can damage the motor when a short-circuit occurs.
Note:
For bit 00:
The bit is only active for p0601 = 1.
Description:
Displays the encoder diagnostics for the PROFIdrive interface.
Description:
Trace functionality for OEM encoder manufacturers.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Description:
Sets the mode to reset the actual value in XIST_ERW (CO: r4653).
Value:
0:
Inactive
1:
Reset with zero mark
2:
Reset with BICO
3:
Reset with selected zero mark
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: r4653, r4654, p4655
Note:
The absolute value is only valid after passing the zero mark.
If value = 1:
The value in XIST1_ERW is reset when passing every zero mark.
If value = 2:
The value in XIST1_ERW is reset with a 0/1 edge via binector input p4655.
p4621[0...n]
Motor temperature sensor configuration / Mot_temp_sens cfg
Access level:
2
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(3), T
Scaling:
-
Dyn. index:
MDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - 0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
De-activate PTC short-circuit monitoring
Yes
No
8016
r4640[0...95]
Encoder diagnostics state machine / Enc diag stat_ma
Access level:
4
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
p4641[0...2]
OEM encoder diagnostic signal selection / OEM enc diag sel
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 65535
0
p4652[0...2]
XIST1_ERW reset mode / XIST1_ERW res mode
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4750
Min Max
Factory
setting
0 3 0
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...