SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
535
2 Parameters
2.2 List of parameters
Description:
Setting parameter for the run sequence of instance LIM 0 within the run-time group set in p20234.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source of input quantity X of instance LIM 1 of the limiter.
Description:
Setting parameter for the upper limit value LU of instance LIM 1 of the limiter.
Description:
Setting parameter for the lower limit value LL of instance LIM 1 of the limiter.
Description:
Display parameter for the limited output quantity Y of instance LIM 1 of the limiter.
Description:
Display parameter of instance LIM 1 of limiter QU (upper limit reached), i.e. QU = 1 for X >= LU.
p20235
LIM 0 run sequence / LIM 0 RunSeq
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7260
Min Max
Factory
setting
0 32000
640
p20236
CI: LIM 1 input X / LIM 1 input X
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7260
Min Max
Factory
setting
- - 0
p20237
LIM 1 upper limit value LU / LIM 1 upper lim LU
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7260
Min Max
Factory
setting
-340.28235E36 340.28235E36 0.0000
p20238
LIM 1 lower limit value LL / LIM 1 lower lim LL
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7260
Min Max
Factory
setting
-340.28235E36 340.28235E36 0.0000
r20239
CO: LIM 1 output Y / LIM 1 output Y
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7260
Min Max
Factory
setting
- - -
r20240
BO: LIM 1 input quantity at the upper limit QU / LIM 1 QU
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7260
Min Max
Factory
setting
- - -
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......