2 Parameters
2.2 List of parameters
SINAMICS G120D
352
List Manual (LH14), 01/2016, A5E33842313
Description:
Sets the signal source to activate modulo correction.
Dependency:
Refer to: p2576
Note:
When the signal state changes at the binector input, this only becomes effective in the "ready for switching on" state.
Selecting modulo correction:
The actual position setpoint in the modulo range is corrected. The position actual value differs from the position
setpoint by the following error and can also leave the modulo range.
De-selecting modulo correction:
It is based on the actual position actual value.
Description:
Sets the signal source for the software limit switch minus.
Dependency:
Refer to: p2579, p2580, p2581, p2582
Refer to: A07469, A07477, A07479, F07481
Notice:
A change to the software limit switch becomes immediately effective.
If the software limit switch is changed, then this results in the positions in the traversing blocks being checked.
Note:
The following applies for the setting of the software limit switch:
Software limit switch minus < software limit switch plus
Description:
Sets the signal source for the software limit switch plus.
Dependency:
Refer to: p2578, p2580, p2581, p2582
Refer to: A07470, A07478, A07480, F07482
Notice:
A change to the software limit switch becomes immediately effective.
If the software limit switch is changed, then this results in the positions in the traversing blocks being checked.
Note:
The following applies for the setting of the software limit switch:
Software limit switch minus < software limit switch plus
Description:
Sets the software limit switch in the negative direction of travel.
Dependency:
Refer to: p2578, p2579, p2581, p2582
p2577
BI: EPOS modulo correction activation / Modulo corr act
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3630, 3635
Min Max
Factory
setting
- - 0
p2578
CI: EPOS software limit switch minus signal source / SW limSw Min S_src
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
U32 / Integer32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3630
Min Max
Factory
setting
- - 2580[0]
p2579
CI: EPOS software limit switch plus signal source / SW limSwPlus S_src
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
U32 / Integer32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3630
Min Max
Factory
setting
- - 2581[0]
p2580
CO: EPOS software limit switch minus / SW limSwitch minus
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3630
Min Max
Factory
setting
-2147482648 [LU]
2147482647 [LU]
-2147482648 [LU]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......