SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
361
2 Parameters
2.2 List of parameters
Description:
Sets the signal source for the reference cam.
Dependency:
Refer to: p2607
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description:
Sets the signal source for the reversing cam in the negative direction of travel.
1 signal: Reversing cam not reached.
0 signal: Reversing cam reached.
Dependency:
Refer to: p2614
Note:
If, during the search for reference from the reversing cam minus and plus, a 0 signal is detected, then the axis
remains stationary (at standstill).
Description:
Sets the signal source for the reversing cam in the negative direction of travel.
1 signal: Reversing cam not reached.
0 signal: Reversing cam reached.
Dependency:
Refer to: p2613
Note:
If, during the search for reference from the reversing cam minus and plus, a 0 signal is detected, then the axis
remains stationary (at standstill).
Description:
Sets the maximum number of traversing blocks that are available.
Dependency:
Refer to: p2616, p2617, p2618, p2619, p2620, p2621, p2622, p2623, p2624
p2612
BI: EPOS search for reference reference cam / Ref_cam
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3612
Min Max
Factory
setting
- - 0
p2613
BI: EPOS search for reference reversing cam minus / Rev minus
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3612
Min Max
Factory
setting
- - 1
p2614
BI: EPOS search for reference reversing cam plus / Rev plus
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3612
Min Max
Factory
setting
- - 1
p2615
EPOS maximum number of traversing blocks / Trav_block qty max
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
Unsigned8
Can be changed:
C(17)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3616
Min Max
Factory
setting
1 16
16
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...