2 Parameters
2.2 List of parameters
SINAMICS G120D
510
List Manual (LH14), 01/2016, A5E33842313
Description:
Setting parameter for the run-time group in which instance SUB 0 of the subtractor is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance SUB 0 within the run-time group set in p20104.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source of minuend X1 and subtrahend X2 of instance SUB 1 of the subtractor.
Index:
[0] = Minuend X1
[1] = Subtrahend X2
Description:
Display parameter for the difference Y = X1 - X2 of instance SUB 1 of the subtractor.
Description:
Setting parameter for the run-time group in which instance SUB 1 of the subtractor is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
p20104
SUB 0 run-time group / SUB 0 RTG
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7220
Min Max
Factory
setting
5 9999
9999
p20105
SUB 0 run sequence / SUB 0 RunSeq
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7220
Min Max
Factory
setting
0 32000
240
p20106[0...1]
CI: SUB 1 inputs / SUB 1 inputs
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7220
Min Max
Factory
setting
- - 0
r20107
CO: SUB 1 difference Y / SUB 1 difference Y
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7220
Min Max
Factory
setting
- - -
p20108
SUB 1 run-time group / SUB 1 RTG
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7220
Min Max
Factory
setting
5 9999
9999
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......