2 Parameters
2.2 List of parameters
SINAMICS G120D
220
List Manual (LH14), 01/2016, A5E33842313
Description:
Displays the torque setpoint before entering the supplementary torque.
For closed-loop speed control, r1508 corresponds to the speed controller output; for closed-loop torque control,
r1508 corresponds to the torque setpoint of the signal source assigned in p1503.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Description:
Sets the signal source for supplementary torque 1.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Description:
Sets the signal source for scaling the supplementary torque 1.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Description:
Sets the signal source for supplementary torque 2.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Description:
Sets the scaling for supplementary torque 2.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
r1508
CO: Torque setpoint before supplementary torque / M_set bef. M_suppl
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2003
Dyn. index:
-
Unit group:
7_1
Unit selection:
p0505
Func. diagram:
6030, 6060, 6722
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]
p1511[0...n]
CI: Supplementary torque 1 / M_suppl 1
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
p2003
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
6020, 6060
Min Max
Factory
setting
- - 0
p1512[0...n]
CI: Supplementary torque 1 scaling / M_suppl 1 scal
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
5060, 6060
Min Max
Factory
setting
- - 0
p1513[0...n]
CI: Supplementary torque 2 / M_suppl 2
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
p2003
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
6020, 6060
Min Max
Factory
setting
- - 0
p1514[0...n]
Supplementary torque 2 scaling / M_suppl 2 scal
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
PERCENT
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
6020, 6060
Min Max
Factory
setting
-2000.0 [%]
2000.0 [%]
100.0 [%]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......