2 Parameters
2.2 List of parameters
SINAMICS G120D
278
List Manual (LH14), 01/2016, A5E33842313
Description:
Sets the start for the SIC/SCC telegram (p60122) in the send words (p2051, p2061).
Dependency:
Refer to: p0922, p2079, p60122
Note:
For setting p0922/p2079, the value is preset to the end of the PZD telegram.
For p0922 equal to 999 and p2079 not equal to 999, the preset value can be increased.
The value must be set again after changing p0922/p2079.
Description:
Sets the response for the receive value (r2090) after PZD failure.
Description:
Displays the PROFIBUS address of the sender from which the process data (PZD) is received.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
Note:
Value range:
0 - 125: Bus address of the sender
65535: Not assigned
Description:
Displays the PZD byte offset in the PROFIdrive receive telegram (controller output).
p2071
PROFIdrive SIC/SCC start send / SIC/SCC start send
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
Unsigned8
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2423
Min Max
Factory
setting
0 30
0
p2072
Response receive value after PZD failure / Resp aft PZD fail
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - 0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Unconditionally open holding brake (p0855) Freeze value
Zero the value
-
r2074[0...11]
PROFIdrive diagnostics bus address PZD receive / Diag addr recv
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
r2075[0...11]
PROFIdrive diagnostics telegram offset PZD receive / Diag offs recv
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2410
Min Max
Factory
setting
- - -
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......