SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
143
2 Parameters
2.2 List of parameters
Dependency:
BI: p0897 = 0 signal
The function "parking axis" is not selected.
BI: p0897 = 1 signal
The function "parking axis" is selected.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
After it has been selected the "parking axis" function only becomes active when the pulses are suppressed.
Description:
Display and connector output for the control word of the sequence control.
Note:
OC: Operating condition
Description:
Display and BICO output for the status word of the sequence control.
Note:
For bits 00, 01, 02, 04, 05, 06, 09:
For PROFIdrive, these signals are used for status word 1.
r0898.0...14
CO/BO: Control word sequence control / STW seq_ctrl
Access level:
2
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2501
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
ON/OFF1
Yes
No
-
01
OC / OFF2
Yes
No
-
02
OC / OFF3
Yes
No
-
03
Operation enable
Yes
No
-
04
Ramp-function generator enable
Yes
No
-
05
Continue ramp-function generator
Yes
No
-
06
Speed setpoint enable
Yes
No
-
07
Command open brake
Yes
No
-
08
Jog 1
Yes
No
3001
09
Jog 2
Yes
No
3001
10
Master control by PLC
Yes
No
-
12
Speed controller enable
Yes
No
-
14
Command close brake
Yes
No
-
r0899.0...13
CO/BO: Status word sequence control / ZSW seq_ctrl
Access level:
2
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2503
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Ready for switching on
Yes
No
-
01
Ready
Yes
No
-
02
Operation enabled
Yes
No
-
03
Jog active
Yes
No
-
04
No coasting active
OFF2 inactive
OFF2 active
-
05
No Quick Stop active
OFF3 inactive
OFF3 active
-
06
Switching-on inhibited active
Yes
No
-
07
Drive ready
Yes
No
-
08
Controller enable
Yes
No
-
09
Control request
Yes
No
-
11
Pulses enabled
Yes
No
-
12
Open holding brake
Yes
No
-
13
Command close holding brake
Yes
No
-
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......