2 Parameters
2.2 List of parameters
SINAMICS G120D
452
List Manual (LH14), 01/2016, A5E33842313
Description:
Sets the velocity hysteresis for the SSM feedback signal to detect standstill (n < nx).
Dependency:
Refer to: C01711
Note:
The velocity hysteresis is effective only if the function is enabled (p9501.16 = 1).
The parameter is included in the crosswise data comparison of the two monitoring channels.
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
Description:
Sets the velocity tolerance for the "SAM" function.
Dependency:
Refer to: C01706
Note:
SAM: Safe Acceleration Monitor (safe acceleration monitoring)
Description:
Sets the delay time for the SLS changeover for the function "safely limited speed" (SLS).
When transitioning from a higher to a lower safely limited velocity/speed stage, within this delay time, the "old"
velocity stage remains active.
Even if SLS is activated from the state "SLS in active", then this delay is still applied.
Note:
SLS: Safely Limited Speed
Description:
Sets the delay time for STOP A after STOP B.
Dependency:
Refer to: p9560
Refer to: C01701
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
Description:
Sets the maximum time for the acceptance test mode.
p9547
SI Motion SSM velocity hysteresis (processor 1) / SI Mtn SSM hyst P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2823
Min Max
Factory
setting
0.0010 [rpm]
500.0000 [rpm]
10.0000 [rpm]
p9548
SI Motion SAM actual velocity tolerance (processor 1) / SI mtn SAM tol P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.00 [rpm]
120000.00 [rpm]
300.00 [rpm]
p9551
SI Motion SLS changeover delay time (processor 1) / SI Mtn SLS t P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2819, 2820
Min Max
Factory
setting
0.00 [ms]
600000.00 [ms]
100.00 [ms]
p9556
SI Motion pulse suppression delay time (processor 1) / SI Mtn IL t_del P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2819
Min Max
Factory
setting
0.00 [ms]
3600000.00 [ms]
600000.00 [ms]
p9558
SI Motion acceptance test mode time limit (processor 1) / SI Mtn acc t P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
5000.00 [ms]
100000.00 [ms]
40000.00 [ms]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......