SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
103
2 Parameters
2.2 List of parameters
p0523[0]: parameter number
p0523[1]: parameter number
p0523[2]: parameter number
...
p0523[19]: parameter number
Dependency:
Refer to: p0514
Description:
Sets the parameters with reference value in p0514[9] for the specific scaling.
p0524[0]: parameter number
p0524[1]: parameter number
p0524[2]: parameter number
...
p0524[19]: parameter number
Dependency:
Refer to: p0514
Description:
Display and setting the code number of the load gearbox.
Description:
Maximum permissible input speed at the load gearbox.
The following applies when calculating the maximum speed (p1082):
- for p0324 = 0 or p0532 = 0 or p0542 = 0, p0322 is used.
- for p0324 > 0, p0532 > 0 and p0542 > 0, the minimum value from the parameters is used.
Description:
Maximum permissible input torque at the load gearbox.
p0524[0...19]
Scaling specific parameters referred to p0514[9] / Scal spec p514[9]
Access level:
3
Calculated:
p0340 = 1
Data type:
Unsigned32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 4294967295
0
p0541[0...n]
Load gearbox code number / Load grbx CodeNo
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
T
Scaling:
-
Dyn. index:
MDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 4294967295
0
p0542[0...n]
Load gearbox maximum speed / Load grbx n_max
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
MDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 [rpm]
340.28235E36 [rpm]
0 [rpm]
p0543[0...n]
Load gearbox maximum torque / Load grbx M_max
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
MDS
Unit group:
7_1
Unit selection:
p0505
Func. diagram:
-
Min Max
Factory
setting
0 [Nm]
340.28235E36 [Nm]
0 [Nm]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......