2 Parameters
2.2 List of parameters
SINAMICS G120D
238
List Manual (LH14), 01/2016, A5E33842313
Description:
Sets the time constant to calculate the d current DC component difference (combination current) to add to the d
current controller actual value.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1), "Dynamic Drive Control" (DDC, p0096
= 2)
Note:
It is not added for p1731 = 0.
Description:
Display and connector output for the direct axis voltage setpoint Ud.
Index:
[0] = Unsmoothed
[1] = Smoothed with p0045
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Description:
Display and connector output for the quadrature axis voltage setpoint Uq.
Index:
[0] = Unsmoothed
[1] = Smoothed with p0045
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Description:
Defines the gain of the controller for resonance damping for operation with sensorless vector control in the range that
current is injected.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Description:
Sets the speed threshold value to detect a stalled motor.
p1731[0...n]
Isd controller combination current time component / Isd ctr I_combi T1
Access level:
4
Calculated:
p0340 = 1,3,4
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.00 [ms]
10000.00 [ms]
0.00 [ms]
r1732[0...1]
CO: Direct-axis voltage setpoint / Direct U set
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2001
Dyn. index:
-
Unit group:
5_1
Unit selection:
p0505
Func. diagram:
5700, 5714, 6714,
5718
Min Max
Factory
setting
- [Vrms]
- [Vrms]
- [Vrms]
r1733[0...1]
CO: Quadrature-axis voltage setpoint / Quad U set
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2001
Dyn. index:
-
Unit group:
5_1
Unit selection:
p0505
Func. diagram:
5700, 5714, 5718,
6714, 6719
Min Max
Factory
setting
- [Vrms]
- [Vrms]
- [Vrms]
p1740[0...n]
Gain resonance damping for encoderless closed-loop control / Gain res_damp
Access level:
3
Calculated:
p0340 = 1,3,4
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.000 10.000
0.025
p1744[0...n]
Motor model speed threshold stall detection / MotMod n_thr stall
Access level:
4
Calculated:
p0340 = 1,3
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
-
Min Max
Factory
setting
0.00 [rpm]
210000.00 [rpm]
100.00 [rpm]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......