2 Parameters
2.2 List of parameters
SINAMICS G120D
356
List Manual (LH14), 01/2016, A5E33842313
Description:
Sets the signal source for the externally limited maximum velocity.
Index:
[0] = Setpoint limit absolute
[1] = Setpoint limiting positive
[2] = Setpoint limiting negative
Dependency:
Refer to: r2524, p2571, p2593
Warning:
In order that the externally limited velocity can be effective for the EPOS operating modes, connector input p2593
must be correctly interconnected.
Description:
Sets the signal source to start the "search for reference" or "flying referencing".
BI: p2595 = 0/1 signal
Referencing is started.
BI: p2595 = 1/0 signal
Referencing is interrupted.
Dependency:
Refer to: p2597, p2598, p2599, r2684
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Search for reference (BI: p2597 = 0 signal):
The reference point approach can only be activated (0/1 edge) after traversing motion that is being processed has
been completed.
With the start, where relevant, the state signal "reference point set" (r2684.11) is reset.
Flying referencing (BI: p2597 = 1 signal):
With the start, the state signal "reference point set" (r2684.11) is not reset.
Description:
Sets the signal source for the "set reference point".
Dependency:
Refer to: p2598, p2599, r2684
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Reference point setting is effective in the following operating states:
- in the basic state.
- for FIXED STOP with progress condition END (corresponds to the initial state).
- for traversing block interrupted via BI: p2640 = 0 signal (intermediate stop).
- for EPOS not enabled (BI: p2656 = 0 signal) and position actual value valid (BI: p2658 = 1 signal).
p2594[0...2]
CI: EPOS Maximum velocity externally limited / v_Max ext lim
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
p2000
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3630
Min Max
Factory
setting
- - 0
p2595
BI: EPOS referencing start / Ref start
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3612, 3625, 3614
Min Max
Factory
setting
- - 0
p2596
BI: EPOS set reference point / Set ref_pt
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3612
Min Max
Factory
setting
- - 0
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......