2 Parameters
2.2 List of parameters
SINAMICS G120D
546
List Manual (LH14), 01/2016, A5E33842313
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance NOT 5 within the run-time group set in p20306.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source of input quantities X0, X1, X2, X3 of instance ADD 2 of the adder.
Index:
[0] = Input X0
[1] = Input X1
[2] = Input X2
[3] = Input X3
Description:
Display parameter for the output quantity Y = X0 + X1 + X2 + X3 of instance ADD 2 of the adder.
Description:
Setting parameter for the run-time group in which the instance ADD 2 of the adder is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance ADD 2 within the run-time group set in p20310.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20307
NOT 5 run sequence / NOT 5 RunSeq
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7216
Min Max
Factory
setting
0 32000
780
p20308[0...3]
CI: ADD 2 inputs / ADD 2 inputs
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7220
Min Max
Factory
setting
- - 0
r20309
CO: ADD 2 output Y / ADD 2 output Y
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7220
Min Max
Factory
setting
- - -
p20310
ADD 2 run-time group / ADD 2 RTG
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7220
Min Max
Factory
setting
5 9999
9999
p20311
ADD 2 run sequence / ADD 2 RunSeq
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7220
Min Max
Factory
setting
0 32000
800
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......