SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
77
2 Parameters
2.2 List of parameters
Description:
Displays the actual rotor resistance (phase value).
The parameter is affected by the motor temperature model.
Dependency:
Refer to: p0354, p0620
Note:
In each case, only the rotor resistance of the active Motor Data Set is included with the rotor temperature of the
thermal motor model.
This parameter is not used for synchronous motors (p0300 = 2xx).
Description:
Maximum angle when calculating the polynomial function to decouple the magnetic flux axes for permanent-magnet
synchronous motors (see p0398, p0399).
Description:
Selects the encoder from the list of encoder types supported.
Value:
0:
No encoder
3001: 1024 HTL A/B R
3003: 2048 HTL A/B R
3005: 1024 HTL A/B
3007: 2048 HTL A/B
9999: User-defined
Notice:
An encoder type with p0400 < 9999 defines an encoder for which there is an encoder parameter list.
When selecting a catalog encoder (p0400 < 9999) the parameters from the encoder parameter list cannot be
changed (write protection). To remove write protection, the encoder type should be set to a third-party encoder
(p0400 = 9999).
Note:
The encoder data (e.g. pulse number p0408) can only be changed when p0400 = 9999.
Description:
Selects the encoder from the list of encoder types supported.
Value:
0:
No encoder
3001: 1024 HTL A/B R
3003: 2048 HTL A/B R
3005: 1024 HTL A/B
3007: 2048 HTL A/B
3081: SSI, Singleturn, 24 V
3082: SSI, Multiturn 4096, 24 V
r0396[0...n]
Actual rotor resistance / R_rotor act
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
MDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- [ohm]
- [ohm]
- [ohm]
p0397[0...n]
Angle magnetic decoupling maximum angle / Magn decpl max_ang
Access level:
4
Calculated:
p0340 = 1,2
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
MDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.0 [°]
90.0 [°]
90.0 [°]
p0400[0...n]
Encoder type selection / Enc_typ sel
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
1
Calculated:
-
Data type:
Integer16
Can be changed:
C(1, 4)
Scaling:
-
Dyn. index:
EDS
Unit group:
-
Unit selection:
-
Func. diagram:
4700, 4704
Min Max
Factory
setting
0 9999
0
p0400[0...n]
Encoder type selection / Enc_typ sel
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
Integer16
Can be changed:
C(1, 4)
Scaling:
-
Dyn. index:
EDS
Unit group:
-
Unit selection:
-
Func. diagram:
4700, 4704
Min Max
Factory
setting
0 10100
0
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......