2 Parameters
2.2 List of parameters
SINAMICS G120D
314
List Manual (LH14), 01/2016, A5E33842313
Description:
Sets the value for fixed value 5 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Description:
Sets the value for fixed value 6 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Description:
Sets the value for fixed value 7 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Description:
Sets the value for fixed value 8 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Description:
Sets the value for fixed value 9 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2205[0...n]
CO: Technology controller fixed value 5 / Tec_ctr fix val 5
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
PERCENT
Dyn. index:
DDS, p0180
Unit group:
9_1
Unit selection:
p0595
Func. diagram:
7950
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
50.00 [%]
p2206[0...n]
CO: Technology controller fixed value 6 / Tec_ctr fix val 6
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
PERCENT
Dyn. index:
DDS, p0180
Unit group:
9_1
Unit selection:
p0595
Func. diagram:
7950
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
60.00 [%]
p2207[0...n]
CO: Technology controller fixed value 7 / Tec_ctr fix val 7
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
PERCENT
Dyn. index:
DDS, p0180
Unit group:
9_1
Unit selection:
p0595
Func. diagram:
7950
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
70.00 [%]
p2208[0...n]
CO: Technology controller fixed value 8 / Tec_ctr fix val 8
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
PERCENT
Dyn. index:
DDS, p0180
Unit group:
9_1
Unit selection:
p0595
Func. diagram:
7950
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
80.00 [%]
p2209[0...n]
CO: Technology controller fixed value 9 / Tec_ctr fix val 9
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
PERCENT
Dyn. index:
DDS, p0180
Unit group:
9_1
Unit selection:
p0595
Func. diagram:
7950
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
90.00 [%]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......