SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
381
2 Parameters
2.2 List of parameters
Description:
Displays the effective torque setpoint when reaching the fixed stop (referred to CI: p1522, CI: p1523).
Dependency:
Refer to: p1520, p1521, p1522, p1523, r2676
Description:
Sets a fixed setpoint for the position.
Dependency:
Refer to: p2642, p2648
Note:
As standard, the following BICO interconnection is established: CI: p2642 = r2690
Description:
Sets a fixed setpoint for the velocity.
Dependency:
Refer to: p2643
Note:
As standard, the following BICO interconnection is established: CI: p2643 = r2691
Description:
Sets a fixed setpoint for the acceleration override.
Dependency:
Refer to: p2572, p2644
Note:
As standard, the following BICO interconnection is established: CI: p2644 = r2692
The percentage value refers to the maximum acceleration (p2572).
Description:
Sets a fixed setpoint for the deceleration override.
Dependency:
Refer to: p2573, p2645
Note:
As standard, the following BICO interconnection is established: CI: p2645 = r2693
The percentage value refers to the maximum deceleration (p2573).
r2687
CO: EPOS torque setpoint / M_set
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3616, 3617
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]
p2690
CO: EPOS position fixed setpoint / Pos fixed value
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3618
Min Max
Factory
setting
-2147482648 [LU]
2147482647 [LU]
0 [LU]
p2691
CO: EPOS velocity fixed setpoint / v fixed value
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
Unsigned32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3618
Min Max
Factory
setting
1 [1000 LU/min]
40000000 [1000 LU/min]
600 [1000 LU/min]
p2692
CO: EPOS acceleration override, fixed setpoint / a_over fixed val
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3618
Min Max
Factory
setting
0.100 [%]
100.000 [%]
100.000 [%]
p2693
CO: EPOS deceleration override, fixed setpoint / -a_over fixed val
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3618
Min Max
Factory
setting
0.100 [%]
100.000 [%]
100.000 [%]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......