2 Parameters
2.2 List of parameters
SINAMICS G120D
402
List Manual (LH14), 01/2016, A5E33842313
Description:
Successfully completed component of the last rotating measurement carried out.
Dependency:
Refer to: r3925
Note:
The parameter is a copy of p1959.
Description:
Configuration of voltage generation for the various MotID sections in the case of the most recent successful MotID.
r3928[0...n]
Rotating measurement configuration / Rot meas config
Access level:
3
Calculated:
p0340 = 1
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
01
Saturation characteristic identification
Yes
No
-
02
Moment of inertia identification
Yes
No
-
03
Re-calculates the speed controller
parameters
Yes
No
-
04
Speed controller optimization (vibration test) Yes
No
-
05
q leakage inductance ident. (for current
controller adaptation)
Yes
No
-
11
Do not change the controller parameters
during the measurement
Yes
No
-
12
Measurement shortened
Yes
No
-
13
After measurement direct transition into
operation
Yes
No
-
14
Calculate speed actual value smoothing
time
Yes
No
-
r3929[0...n]
Motor data identification modulated voltage generation / MotID U_gen mod
Access level:
4
Calculated:
p0340 = 1
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Wobble U_generate to determine dead-time
correction
Yes
No
-
01
Wobble U_generate to determine stator
resistance
Yes
No
-
02
Wobble U_generation to determine rotor
time constant
Yes
No
-
03
Wobble U_generation to determine leakage
inductance
Yes
No
-
04
Wobble U_generation to determine dynamic
leakage inductance
Yes
No
-
05
Wobble U_generation to determine
magnetizing inductance
Yes
No
-
08
Alternating U_generate to determine dead-
time correction
Yes
No
-
09
Alternating U_generate to determine stator
resistance
Yes
No
-
10
Alternating U_generate to determine rotor
time constant
Yes
No
-
11
Alternating U_generate to determine
leakage inductance
Yes
No
-
12
Alternating U_generate to determine dyn.
leakage inductance
Yes
No
-
13
Alternating U_generate to determine
magnetizing inductance
Yes
No
-
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......