2 Parameters
2.2 List of parameters
Note:
The encoder adjustment is initiated with p2507 = 2. The status is displayed using the other values.
In order to permanently save the determined position offset (p2525) and the DDS number (p2733), they must be
saved in a non-volatile fashion (p0971, p0977).
This adjustment can only be initiated for an absolute encoder.
Description:
Sets the signal source for the function "activate reference mark search".
Index:
[0] = Position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency:
Refer to: p0490, p2502, p2509, r2684
Refer to: A07495
Notice:
When activating the function "set position actual value" while the function "reference mark search" is activated, then
the function "reference mark search" is automatically de-activated.
Note:
The function can only be activated using a 0/1 signal if no reference function is active (r2526.2).
If "reference mark search" and "measuring probe evaluation" are simultaneously activated, then no function is
activated and the actual function is interrupted.
Description:
Sets the signal source for the function "activate measuring probe evaluation".
0/1 signal:
The function "activate measuring probe evaluation" is started.
Index:
[0] = Position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency:
Refer to: p0488, p0489, p0490, p2502, p2508, p2510, p2511, p2517, p2518
Refer to: A07495
Notice:
When the "set position actual value" is activated while the function "measuring probe evaluation" is activated, then
the function "measuring probe evaluation" is automatically de-activated.
Note:
The function can only be activated using a 0/1 signal if no reference function is active (r2526.2).
If "reference mark search" and "measuring probe evaluation" are simultaneously activated, then no function is
activated and the actual function is interrupted.
p2508[0...3]
BI: LR activate reference mark search / Ref_mark act
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4010
Min Max
Factory
setting
- - [0]
2684.0
[1] 0
[2] 0
[3] 0
p2509[0...3]
BI: LR activate measuring probe evaluation / MT_eval act
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4010
Min Max
Factory
setting
- - [0]
2684.1
[1] 0
[2] 0
[3] 0
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......