SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
133
2 Parameters
2.2 List of parameters
Description:
Sets the signal source to select the Drive Data Set, bit 1 (DDS, bit 1).
Dependency:
Refer to: r0051, r0837
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description:
Sets the freely-assignable motor number for the drive data set changeover.
If the same motor is driven by different drive data sets, the same motor number must also be entered in these data
sets.
If the motor is also switched with the drive data set, different motor numbers must be used. In this case, the data set
can only be switched when the pulse inhibit is set.
Note:
If the motor numbers are identical, the same thermal motor model is used for calculation after data set changeover. If
different motor numbers are used, different models are also used for calculating (the inactive motor cools down in
each case).
For the same motor number, the correction values of the Rs, Lh or kT adaptation are applied for the data set
changeover (refer to r1782, r1787, r1797).
Description:
Displays the status word for the drive data set changeover.
Note:
For bit 02:
A data set changeover is delayed by the time required for the internal parameter calculation.
For bit 04:
A data set changeover is only carried out when the armature short circuit is not activated.
For bit 05:
A data set changeover is only carried out when pole position identification is not running.
For bit 07:
A data set changeover is only carried out when rotating measurement is not running.
For bit 08:
A data set changeover is only carried out when motor data identification is not running.
p0821[0...n]
BI: Drive Data Set selection DDS bit 1 / DDS select., bit 1
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
C(15), T
Scaling:
-
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
8565, 8570
Min Max
Factory
setting
- - 0
p0826[0...n]
Motor changeover motor number / Mot_chng mot No.
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
C(3), T
Scaling:
-
Dyn. index:
MDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 3 0
r0835.2...8
CO/BO: Data set changeover status word / DDS_ZSW
Access level:
2
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
8575
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
02
Internal parameter calculation active
Yes
No
-
04
Armature short circuit active
Yes
No
-
05
Identification running
Yes
No
-
06
Friction characteristic plot running
Yes
No
-
07
Rotating measurement running
Yes
No
-
08
Motor data identification running
Yes
No
-
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......