SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
375
2 Parameters
2.2 List of parameters
Dependency:
Refer to: r2526, p2660
Description:
Sets the signal source for the feedback signal "clamping active for travel to fixed stop".
BI: p2663 = 1 signal
Clamping is active
BI: p2663 = 0 signal
Clamping is not active.
Dependency:
Refer to: r2526
Note:
The feedback signal from "terminals active" is, for the factory setting, dependent on the signal BO: r2526.8 (terminals
active when moving to a fixed stop).
Description:
Displays the actual absolute position setpoint.
Dependency:
Refer to: p2530
Note:
As standard, the following BICO interconnection is established: CI: p2530 = r2665
Description:
Displays the actual velocity setpoint.
Dependency:
Refer to: p2531
Note:
As standard, the following BICO interconnection is established: CI: p2531 = r2666
Description:
Displays the actual effective value for backlash compensation.
Dependency:
Refer to: p2516
Note:
As standard, the following BICO interconnection is established: CI: p2516 = r2667
p2663
BI: EPOS clamping active feedback signal / Clamping active FS
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3616
Min Max
Factory
setting
- - 2526.8
r2665
CO: EPOS position setpoint / s_set
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3635
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]
r2666
CO: EPOS velocity setpoint / v_set
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3635
Min Max
Factory
setting
- [1000 LU/min]
- [1000 LU/min]
- [1000 LU/min]
r2667
CO: EPOS backlash compensation value / Backlash value
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
3635
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......