SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
455
2 Parameters
2.2 List of parameters
Description:
Setting to select and de-select the acceptance test mode.
Value:
0:
[00 hex] De-select the acceptance test mode
172:
[AC hex] Select the acceptance test mode
Dependency:
Refer to: p9558, r9571, p9601
Refer to: C01799
Note:
Acceptance test mode can only be selected if the motion monitoring functions, which are integrated in the drives, are
enabled (p9601.2/p9801.2).
Description:
Displays the status of the acceptance test mode.
Value:
0:
[00 hex] Acc_mode inactive
12:
[0C hex] Acc_mode not possible due to POWER ON fault
13:
[0D hex] Acc_mode not possible due to incorrect ID in p9570
15:
[0F hex] Acc_mode not possible due to expired Acc_timer
172:
[AC hex] Acc_mode active
Dependency:
Refer to: p9558, p9570
Refer to: C01799
Description:
Sets the reference value to define the brake ramp.
The rate of rise of the brake ramp depends upon p9581 (reference value) and p9583 (monitoring time).
Dependency:
Refer to: p9582, p9583
Description:
Sets the delay time for monitoring the brake ramp.
Monitoring of the brake ramp starts once the delay time has elapsed.
Dependency:
Refer to: p9581, p9583
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
Internally, the set time is limited downwards to 2 safety monitoring clock cycles (2 * 12 ms).
p9570
SI Motion acceptance test mode (processor 1) / SI Mtn acc_mod P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0000 hex
00AC hex
0000 hex
r9571
SI Motion acceptance test status (processor 1) / SI Mtn acc_status
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0000 hex
00AC hex
-
p9581
SI Motion brake ramp reference value (processor 1) / SI Mtn ramp ref P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
600.0000 [rpm]
240000.0000 [rpm]
1500.0000 [rpm]
p9582
SI Motion brake ramp delay time (processor 1) / SI Mtn ramp t P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
10.00 [ms]
99000.00 [ms]
250.00 [ms]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......