2 Parameters
2.2 List of parameters
Description:
Displays the ambient temperature of the motor temperature model (models 2 and 3).
Description:
Displays the stator iron temperature of the motor temperature model (models 2 and 3).
Note:
For motor temperature model 1 (p0612.0 = 1), this parameter is not valid:
Description:
Displays the stator winding temperature of the motor temperature model.
Dependency:
Refer to: F07011, A07012, A07910
Description:
Displays the rotor temperature of the motor temperature model (models 2 and 3).
Note:
For motor temperature model 1 (p0612.0 = 1), this parameter is not valid:
Description:
The non-linear and cross-coupled quadrature axis flux functions are defined using 4 coefficients.
The parameter weights the unsaturated component of the quadrature axis flux function.
Description:
The non-linear and cross-coupled quadrature axis flux functions are defined using 4 coefficients.
r0630[0...n]
Mot_temp_mod ambient temperature / Mod T_ambient
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2006
Dyn. index:
MDS
Unit group:
21_1
Unit selection:
p0505
Func. diagram:
8018
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r0631[0...n]
Mot_temp_mod stator iron temperature / Mod T_stator
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2006
Dyn. index:
MDS
Unit group:
21_1
Unit selection:
p0505
Func. diagram:
8018
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r0632[0...n]
Mot_temp_mod stator winding temperature / Mod T_winding
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2006
Dyn. index:
MDS
Unit group:
21_1
Unit selection:
p0505
Func. diagram:
8017, 8018
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r0633[0...n]
Mot_temp_mod rotor temperature / Mod rotor temp
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2006
Dyn. index:
MDS
Unit group:
21_1
Unit selection:
p0505
Func. diagram:
8018
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
p0634[0...n]
Q flux flux constant unsaturated / PSIQ KPSI UNSAT
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(3), U, T
Scaling:
-
Dyn. index:
MDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.000 [Vsrms]
100.000 [Vsrms]
0.000 [Vsrms]
p0635[0...n]
Q flux quadrature axis current constant unsaturated / PSIQ KIQ UNSAT
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(3), U, T
Scaling:
-
Dyn. index:
MDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......