SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
417
2 Parameters
2.2 List of parameters
Note:
Bit 0 and bit 1 are inverse of one another.
Pe: PROFIenergy profiles
Description:
Sets the signal source to set in the PROFIdrive state S1 "switching-on inhibited".
Dependency:
Refer to: r5613
Note:
Pe: PROFIenergy profiles
Description:
Displays the actual serial number of the Control Unit.
The individual characters of the serial number are displayed in the ASCII code in the indices.
For the commissioning software, the ASCII characters are displayed uncoded.
Dependency:
Refer to: p7765, p7766, p7767, p7768
Notice:
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
Note:
KHP: Know-How Protection
Description:
Sets the reference serial number for the Control Unit.
Using this parameter, if a Control Unit and/or a memory card is replaced at the end customer, the OEM can again
adapt the project to the modified hardware.
Dependency:
Refer to: p7765, p7766, p7767, p7768
Note:
KHP: Know-How Protection
- the OEM may only change this parameter for the use case "Sending encrypted SINAMICS data".
- SINAMICS only evaluates this parameter when powering up from the encrypted "Load into file system..." output or
when powering up from the encrypted PS files. The evaluation is only made when know-how protection and memory
card copy protection have been activated.
Description:
Displays the status for the write protection and know-how protection.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Pe active
Yes
No
-
01
Pe inactive
Yes
No
-
p5614
BI: Pe set switching-on inhibited signal source / Pe sw on_inh s_src
CU240D-2_PN
CU240D-2_PN_F
CU250D-2_PN_F
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2382
Min Max
Factory
setting
- - 0
r7758[0...19]
KHP Control Unit serial number / KHP CU ser_no
Access level:
3
Calculated:
-
Data type:
Unsigned8
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
p7759[0...19]
KHP Control Unit reference serial number / KHP CU ref ser_no
Access level:
3
Calculated:
-
Data type:
Unsigned8
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
r7760.0...12
CO/BO: Write protection/know-how protection status / Wr_prot/KHP stat
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......