2 Parameters
2.3 Parameters for data sets
SINAMICS G120D
570
List Manual (LH14), 01/2016, A5E33842313
2.3.3
Motor data sets (MDS)
Product: SINAMICS G120D, Version: 4707900, Language: eng, Type: MDS
p0133[0...n]
Motor configuration / Motor config
p0300[0...n]
Motor type selection / Mot type sel
p0301[0...n]
Motor code number selection / Mot code No. sel
p0304[0...n]
Rated motor voltage / Mot U_rated
p0305[0...n]
Rated motor current / Mot I_rated
p0306[0...n]
Number of motors connected in parallel / Motor qty
p0307[0...n]
Rated motor power / Mot P_rated
p0308[0...n]
Rated motor power factor / Mot cos phi rated
p0309[0...n]
Rated motor efficiency / Mot eta_rated
p0310[0...n]
Rated motor frequency / Mot f_rated
p0311[0...n]
Rated motor speed / Mot n_rated
p0312[0...n]
Rated motor torque / Mot M_rated
r0313[0...n]
Motor pole pair number, actual (or calculated) / Mot PolePairNo act
p0314[0...n]
Motor pole pair number / Mot pole pair No.
p0316[0...n]
Motor torque constant / Mot kT
p0318[0...n]
Motor stall current / Mot I_standstill
p0320[0...n]
Motor rated magnetizing current/short-circuit current / Mot I_mag_rated
p0322[0...n]
Maximum motor speed / Mot n_max
p0323[0...n]
Maximum motor current / Mot I_max
p0325[0...n]
Motor pole position identification current 1st phase / Mot PolID I 1st ph
p0326[0...n]
Motor stall torque correction factor / Mot M_stall_corr
p0327[0...n]
Optimum motor load angle / Mot phi_load opt
p0328[0...n]
Motor reluctance torque constant / Mot kT_reluctance
p0329[0...n]
Motor pole position identification current / Mot PolID current
r0330[0...n]
Rated motor slip / Mot slip_rated
r0331[0...n]
Actual motor magnetizing current/short-circuit current / Mot I_mag_rtd act
r0332[0...n]
Rated motor power factor / Mot cos phi rated
r0333[0...n]
Rated motor torque / Mot M_rated
r0334[0...n]
Actual motor-torque constant / Mot kT act
p0335[0...n]
Motor cooling type / Mot cool type
r0337[0...n]
Rated motor EMF / Mot EMF_rated
p0341[0...n]
Motor moment of inertia / Mot M_mom of inert
p0342[0...n]
Ratio between the total and motor moment of inertia / Mot MomInert Ratio
r0343[0...n]
Rated motor current identified / Mot I_rated ident
p0344[0...n]
Motor weight (for the thermal motor model) / Mot weight th mod
r0345[0...n]
Nominal motor starting time / Mot t_start_rated
p0346[0...n]
Motor excitation build-up time / Mot t_excitation
p0347[0...n]
Motor de-excitation time / Mot t_de-excitat
p0350[0...n]
Motor stator resistance cold / Mot R_stator cold
p0352[0...n]
Cable resistance / R_cable
p0354[0...n]
Motor rotor resistance cold / Mot R_r cold
p0356[0...n]
Motor stator leakage inductance / Mot L_stator leak.
p0357[0...n]
Motor stator inductance d axis / Mot L_stator d
p0358[0...n]
Motor rotor leakage inductance / Mot L_rot leak
p0360[0...n]
Motor magnetizing inductance / Mot Lh
p0362[0...n]
Motor saturation characteristic flux 1 / Mot saturat.flux 1
p0363[0...n]
Motor saturation characteristic flux 2 / Mot saturat.flux 2
p0364[0...n]
Motor saturation characteristic flux 3 / Mot saturat.flux 3
p0365[0...n]
Motor saturation characteristic flux 4 / Mot saturat.flux 4
p0366[0...n]
Motor saturation characteristic I_mag 1 / Mot sat. I_mag 1
p0367[0...n]
Motor saturation characteristic I_mag 2 / Mot sat. I_mag 2
p0368[0...n]
Motor saturation characteristic I_mag 3 / Mot sat. I_mag 3
p0369[0...n]
Motor saturation characteristic I_mag 4 / Mot sat. I_mag 4
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......