S
IN
A
MICS
G1
20D
List Manual (LH
14)
, 01
/2016
, A5E338423
13
69
9
3
F
un
ction dia
g
ra
ms
3.
12
Ba
sic po
sitio
n
er
(EPOS
)
F
ig.
3
-91
36
16 – Trave
rsi
ng blo
ck mode
- 3616 -
Function diagram
8
7
6
5
4
3
2
1
fp_3616_97_55.vsd
Basic positioner (EPOS)
G120D CU250D-2
09.12.2015
V4.7.6
Traversing block mode
0
1
0
&
100 %
100 %
Position
+
Position
0
1
p2615
-1
...
0
1
p2631
x
y
Store
0
1
0
[3635.6]
p2657
<3>
<3>
<3>
<3>
<3>
<3>
<3>
A07461-A07472
A07483, A07485-A07487
F07484
+
0
1
0
1
0
1
<3>
[3630.1]
[3650.2]
p2637
(r2526.4)
p2638
(r2526.5)
p2639
(r1407.7)
[3615.7]
p2632
<1>
r2686[0]
r2686[1]
<5>
r2683.10
r2683.11
r2683.12
r2683.13
r2683.14
r2684.12
r2687
<4>
<2>
p2663
(r2526.8)
[3617.6]
[4025.8]
[3617.6]
[4025.8]
[2522.7]
[4025.8]
[3640.7]
p2625
p2626
p2627
p2628
[3640.7]
Trav_blk, blkNo.
-1 ... 15
p2616 (-1)
Trav_block task
1 ... 9
p2621 (1)
Trav_blck task_par
-2147483648 ... 2147483647
p2622 (0)
Trav_block mode
0 ... 65535
p2623 (0)
Trav_block pos
-2147482648 ... 2147482647 [LU]
p2617 (0)
Trav_block v
1 ... 40000000 [1000 LU/min]
p2618 (600)
Trav_block a_over
1.0 ... 100.0 [%]
p2619 (100.0)
Trav_block -a_over
1.0 ... 100.0 [%]
p2620 (100.0)
Trav_block sort
0 ... 1
p2624 (0)
External block change
Actual traversing block
Block number
Task
Task parameter
Task mode
Po
sition
ing mo
de,
rel
ative
Velocity
Acceleration
override
Deceleration
override
Parameter index
Activate traversing task
Signal source feedback signals
Block selection
Torque limits
Status signals
Task ENDLESS_NEG
Task ENDLESS_POS or ENDLESS_NEG
Start of traversing
range
End of traversing range
Velocity
Acceleration override
Deceleration
override
0 = Intermediate stop
0 = Reject traversing
task
Evaluated only in the following cases:
Current job/traversing block and step enabling CONTINUE_EXTERNAL, CONTINUE_EXTERNAL_WAIT,
CONTINUE_EXTERNAL_ALARM.
The tasks are sorted according to their traversing block number in the parameter index (the task with the lowest
number in index 1).
The connector outputs are only supplied from here when the “traversing blocks“ mode is active.
p2615 specifies the maximum number of traversing blocks.
Torque limits are only influenced by the "FIXED STOP" job. A value of 100 % is specified in all other cases.
Motion variables in
"traversing block"
mode
r2678
Ext BlckChg s_act [LU]
r2675
Task act
r2677
Task mode act
r2676
Task para act
r2671
s_set act [LU]
r2672
v_set act [1000 LU/min]
r2673
a_over act [%]
r2674
-a_over act [%]
(0)
Intermediate stop
p2640
(0)
Trav_task reject
p2641
Upper torque limiting effective [3617.7]
Lower torque limiting effective [3617.7]
Torque setpoint
Direct output 1 via traversing block [3645.3]
Direct output 2 via traversing block [3645.3]
Acknowledgment, traversing block activated [3646.3]
Fixed stop reached [3645.3], [3617.7]
Fixed stop clamping torque reached [3645.3], [3617.4]
Travel to fixed stop active [3645.3], [3617.7]
Pos act/set value
<1>
<2>
<3>
<4>
<5>
0
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......