2 Parameters
2.2 List of parameters
Note:
For bit 01:
This bit can be used to execute a control-based ESR.
ESR: Extended Stop and Retract
SAM: Safe Acceleration Monitor (safe acceleration monitoring)
SBR: Safe Brake Ramp (safe brake ramp monitoring)
Description:
Displays the crosswise comparison clock cycle.
The value indicates the clock cycle time with which each individual CDC value is compared between the two
monitoring channels.
Note:
CDC: Crosswise Data Comparison
Description:
For index 0:
Displays the message value that resulted in the STOP F on the drive.
Value = 0:
Processor 1 signaled a STOP F.
Value = 1 ... 999:
Number of the incorrect date in the crosswise data comparison between the monitoring channels.
Value >= 1000:
Additional diagnostic values of the drive.
For index 1:
Displays the value from processor 1 that resulted in the STOP F.
For index 2:
Displays the value from processor 2 that resulted in the STOP F.
Index:
[0] = Message value for CDC
[1] = Processor 1 CDC actual value
[2] = Processor 2 CDC actual value
Dependency:
Refer to: C01711
Note:
The significance of the individual message values is described in message C01711.
CDC: Crosswise Data Comparison
For index 1, 2:
When Safety message C01711 with message value >= 1000 occurs, these indices are not supplied with values.
Description:
Displays the checksum over the checked Safety Integrated parameters of the motion monitoring functions (actual
checksum).
09
Safe pulse suppression active
Yes
No
-
12
Test stop active
Yes
No
-
16
SAM/SBR active
Yes
No
2820
r9724
SI Motion crosswise comparison clock cycle / SI Mtn CDC clk cyc
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- [ms]
- [ms]
- [ms]
r9725[0...2]
SI Motion diagnostics STOP F / SI Mtn Diag STOP F
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
r9728[0...2]
SI Motion actual checksum SI parameters (processor 1) / SI Mtn act CRC P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......