SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
47
2 Parameters
2.2 List of parameters
Description:
Displays the flux actual value.
Index:
[0] = Unsmoothed
[1] = Smoothed
Description:
Displays the actual active power factor.
This value refers to the electrical power of the basic fundamental signals at the output terminals of the converter.
Description:
Displays the actual phase voltage.
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
Note:
The values are determined from the transistor switch-on duration.
Description:
Displays the transformation angle.
Dependency:
Refer to: r1778
Note:
The transformation angle corresponds to the electrical commutation angle.
Description:
Defines whether the motor and drive converter power settings (e.g. rated motor power, p0307) are expressed in [kW]
or [hp].
Depending on the selection, the rated motor frequency (p0310) is either set to 50 Hz or 60 Hz.
For p0100 = 0, 2, the following applies: The power factor (p0308) should be parameterized.
For p0100 = 1, the following applies: The efficiency (p0309) should be parameterized.
r0084[0...1]
CO: Flux actual value / Flux act val
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
6730, 6731
Min Max
Factory
setting
- [%]
- [%]
- [%]
r0087
CO: Actual power factor / Cos phi act
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
r0089[0...2]
Actual phase voltage / U_phase act val
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2001
Dyn. index:
-
Unit group:
5_3
Unit selection:
p0505
Func. diagram:
6719
Min Max
Factory
setting
- [V]
- [V]
- [V]
r0094
CO: Transformation angle / Transformat_angle
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2005
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- [°]
- [°]
- [°]
p0100
IEC/NEMA mot stds / IEC/NEMA mot stds
Access level:
1
Calculated:
-
Data type:
Integer16
Can be changed:
C(1)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 2 0
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......