SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
397
2 Parameters
2.2 List of parameters
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 8th value pair of the friction characteristic.
Dependency:
Refer to: p3827, p3845
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 9th value pair of the friction characteristic.
Dependency:
Refer to: p3828, p3845
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 10th value pair of the friction characteristic.
Dependency:
Refer to: p3829, p3845
Description:
Display and BICO output for the status word of the friction characteristic.
Description:
Display and connector output for the torque of the friction characteristic dependent on the speed.
Dependency:
Refer to: p3842
p3837[0...n]
Friction characteristic value M7 / Friction M7
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
7_1
Unit selection:
p0505
Func. diagram:
7010
Min Max
Factory
setting
-1000000.0000 [Nm]
1000000.0000 [Nm]
0.0000 [Nm]
p3838[0...n]
Friction characteristic value M8 / Friction M8
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
7_1
Unit selection:
p0505
Func. diagram:
7010
Min Max
Factory
setting
-1000000.0000 [Nm]
1000000.0000 [Nm]
0.0000 [Nm]
p3839[0...n]
Friction characteristic value M9 / Friction M9
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
7_1
Unit selection:
p0505
Func. diagram:
7010
Min Max
Factory
setting
-1000000.0000 [Nm]
1000000.0000 [Nm]
0.0000 [Nm]
r3840.0...8
CO/BO: Friction characteristic status word / Friction ZSW
Access level:
2
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7010
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Friction characteristic OK
Yes
No
-
01
Friction characteristic record activated
Yes
No
-
02
Friction characteristic record completed
Yes
No
-
03
Friction characteristic record aborted
Yes
No
-
08
Friction characteristic positive direction
Yes
No
-
r3841
CO: Friction characteristic output / Frict outp
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2003
Dyn. index:
-
Unit group:
7_1
Unit selection:
p0505
Func. diagram:
7010
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......