2 Parameters
2.2 List of parameters
SINAMICS G120D
322
List Manual (LH14), 01/2016, A5E33842313
Description:
Sets the signal source for the setpoint 2 of the technology controller.
Dependency:
Refer to: p2253, p2256
Description:
Sets the scaling for the setpoint 1 of the technology controller.
Dependency:
Refer to: p2253
Description:
Sets the scaling for the setpoint 2 of the technology controller.
Dependency:
Refer to: p2254
Description:
Sets the ramp-up time of the technology controller.
Dependency:
Refer to: p2258
Note:
The ramp-up time is referred to 100 %.
Description:
Sets the ramp-down time of the technology controller.
Dependency:
Refer to: p2257
Note:
The ramp-down time is referred to 100 %.
p2254[0...n]
CI: Technology controller setpoint 2 / Tec_ctrl setp 2
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
U, T
Scaling:
PERCENT
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
7958
Min Max
Factory
setting
- - 0
p2255
Technology controller setpoint 1 scaling / Tec_ctrl set1 scal
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7958
Min Max
Factory
setting
0.00 [%]
100.00 [%]
100.00 [%]
p2256
Technology controller setpoint 2 scaling / Tec_ctrl set2 scal
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7958
Min Max
Factory
setting
0.00 [%]
100.00 [%]
100.00 [%]
p2257
Technology controller ramp-up time / Tec_ctrl t_ramp-up
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7958
Min Max
Factory
setting
0.00 [s]
650.00 [s]
1.00 [s]
p2258
Technology controller ramp-down time / Tec_ctrl t_ramp-dn
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
2
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7958
Min Max
Factory
setting
0.00 [s]
650.00 [s]
1.00 [s]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......