2 Parameters
2.2 List of parameters
SINAMICS G120D
538
List Manual (LH14), 01/2016, A5E33842313
Description:
Sets the signal source for the "accept setting value" signal of instant PT1 1 of the smoothing element.
Description:
Sets the smoothing time constant T in milliseconds of instance PT1 1 of the smoothing element.
Description:
Display parameter for the smoothed output quantity Y of instance PT1 1 of the smoothing element.
Description:
Setting parameter for the run-time group in which instance PT1 1 of the smoothing element is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance PT1 1 within the run-time group set in p20254.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source of input quantity X and of setting value SV of instance INT 0 of the integrator.
p20251
BI: PT1 1 accept setting value S / PT1 1 acc set val
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7262
Min Max
Factory
setting
- - 0
p20252
PT1 1 smoothing time constant in ms / PT1 1 T_smooth ms
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7262
Min Max
Factory
setting
0.00 340.28235E36
0.00
r20253
CO: PT1 1 output Y / PT1 1 output Y
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7262
Min Max
Factory
setting
- - -
p20254
PT1 1 run-time group / PT1 1 RTG
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7262
Min Max
Factory
setting
5 9999
9999
p20255
PT1 1 run sequence / PT1 1 RunSeq
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7262
Min Max
Factory
setting
0 32000
680
p20256[0...1]
CI: INT 0 inputs / INT 0 inputs
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7264
Min Max
Factory
setting
- - 0
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......