2 Parameters
2.2 List of parameters
SINAMICS G120D
474
List Manual (LH14), 01/2016, A5E33842313
Description:
Displays the actual velocity deviation for sensorless actual value sensing.
This value is calculated when setting p9585/p9385.
The actual velocity has a deviation of +/- r9787 for 6 ms * p9585/p9385 within a monitoring time of 1 s.
Dependency:
Refer to: p9585
Note:
For linear axes, the following unit applies: millimeters per minute
For rotary axes, the following unit applies: revolutions per minute
Description:
Displays the numbers of the data items that are currently being compared crosswise on processor 1.
The content of the list of crosswise-compared data is dependent upon the particular application.
Note:
Example:
r9794[0] = 1 (monitoring clock cycle)
r9794[1] = 2 (enable safety functions)
r9794[2] = 3 (F-DI changeover, tolerance time)
...
A complete list of numbers for crosswise-compared data items appears in fault F01611.
Description:
Displays the number of the cross-compared data item which caused STOP F on processor 1.
Dependency:
Refer to: F01611
Note:
A complete list of numbers for crosswise-compared data items appears in fault F01611.
Description:
Displays the checksum for the Safety Integrated parameters checked using checksums on processor 1 (actual
checksum).
Dependency:
Refer to: p9799, r9898
r9787
SI Motion diagnostics sensorless velocity deviation / Diag sl v_dev
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]
r9794[0...19]
SI crosswise comparison list (processor 1) / SI CDC_list P1
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2802
Min Max
Factory
setting
- - -
r9795
SI diagnostics STOP F (processor 1) / SI diag STOP F P1
Access level:
2
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2802
Min Max
Factory
setting
- - -
r9798
SI actual checksum SI parameters (processor 1) / SI act chksm P1
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2800
Min Max
Factory
setting
- - -
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......