SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
291
2 Parameters
2.2 List of parameters
Description:
Sets the second signal source to acknowledge faults.
Note:
A fault acknowledgment is triggered with a 0/1 signal.
Description:
Sets the third signal source to acknowledge faults.
Note:
A fault acknowledgment is triggered with a 0/1 signal.
Description:
Sets the signal source for external fault 1.
Dependency:
Refer to: F07860
Note:
An external fault is triggered with a 1/0 signal.
Description:
Sets the signal source for external fault 2.
Dependency:
Refer to: F07861
Note:
An external fault is triggered with a 1/0 signal.
Description:
Sets the signal source for external fault 3.
External fault 3 is initiated by the following AND logic operation:
- BI: p2108 negated
- BI: p3111
- BI: p3112 negated
Dependency:
Refer to: p3110, p3111, p3112
Refer to: F07862
Note:
An external fault is triggered with a 1/0 signal.
p2104[0...n]
BI: 2nd acknowledge faults / 2nd acknowledge
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
U, T
Scaling:
-
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
2546, 8060
Min Max
Factory
setting
- - 0
p2105[0...n]
BI: 3rd acknowledge faults / 3rd acknowledge
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
U, T
Scaling:
-
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
2546, 8060
Min Max
Factory
setting
- - 0
p2106[0...n]
BI: External fault 1 / External fault 1
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
U, T
Scaling:
-
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
2546
Min Max
Factory
setting
- - 1
p2107[0...n]
BI: External fault 2 / External fault 2
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
U, T
Scaling:
-
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
2546
Min Max
Factory
setting
- - 1
p2108[0...n]
BI: External fault 3 / External fault 3
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
U, T
Scaling:
-
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
2546
Min Max
Factory
setting
- - 1
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......