2 Parameters
2.2 List of parameters
SINAMICS G120D
264
List Manual (LH14), 01/2016, A5E33842313
Description:
Sets the maximum flux setpoint to measure the saturation characteristic.
Description:
Displays the status to check and monitor the states of speed controller optimization.
Description:
Sets the pole position identification technique.
p1980 = 1, 8: The current magnitude is set using p0329.
p1980 = 4, 6: The current magnitude of the first measurement section is set using p0325, the second using p0329.
p1980 = 10: The rated motor current is impressed to align.
The current magnitudes are limited to the rated power unit values.
Value:
1:
Voltage pulsing 1st harmonic
4:
Voltage pulsing 2-stage
6:
Voltage pulsing 2-stage inverse
8:
Voltage pulsing 2nd harmonic, inverse
10:
DC current injection
Dependency:
When commissioning a catalog motor, the technique is automatically selected depending on the motor type being
used.
Refer to: p0325, p0329, p1780
Refer to: F07969
Note:
Voltage pulse technique (p1980 = 1, 4) cannot be applied to operation with sine-wave output filters (p0230).
p1974
Speed_ctrl_opt saturation characteristic rotor flux maximum / n_opt rot_fl max
Access level:
4
Calculated:
p0340 = 1
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
104 [%]
120 [%]
120 [%]
r1979.0...12
BO: Speed_ctrl_opt status / n_opt status
Access level:
4
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Speed controller optimization activated
Yes
No
-
01
Speed controller optimization completed
Yes
No
-
02
Speed controller optimization interrupted
Yes
No
-
04
Enc test active
Yes
No
-
05
Saturation char. identification active
Yes
No
-
06
Moment of inertia identification active
Yes
No
-
07
Recalc. speed controller parameters active
Yes
No
-
08
Speed controller vibration test active
Yes
No
-
09
Magnetizing inductance adapt. active
Yes
No
-
10
Operation with encoder after encoderless
operation
Yes
No
-
11
q-leakage inductance identification
Yes
No
-
12
Moment of inertia estimator inhibited
Yes
No
-
p1980[0...n]
PolID technique / PolID technique
Access level:
3
Calculated:
p0340 = 1,3
Data type:
Integer16
Can be changed:
U, T
Scaling:
-
Dyn. index:
MDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
1 10
4
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......