2 Parameters
2.2 List of parameters
SINAMICS G120D
346
List Manual (LH14), 01/2016, A5E33842313
Description:
Sets the signal source for the signal "traversing command active".
BI: p2554 = 1 signal:
It is signaled that positioning is active and therefore the positioning monitoring is not activated with the signal
"setpoint fixed" (p2551).
Dependency:
Refer to: p2551, r2684
Description:
Sets the signal source for the reference of the internal length units LU to motor revolution for rotary encoders and to
mm for linear encoders.
Dependency:
Refer to: p0404, r2524
Note:
The signal value is used to convert the length unit to the speed or velocity setpoint.
Description:
Display and connector output for the position setpoint after setpoint smoothing.
Description:
Display and connector output for the difference between the position setpoint and the position actual value at the
position controller input.
Description:
Display and connector output for the P component at the output of the position controller (speed setpoint).
p2554
BI: LR signal traversing command active / Sig trav_cmnd act
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4020
Min Max
Factory
setting
- - 2684.15
p2555
CI: LR LU/revolution LU/mm / LU/rev LU/mm
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4015
Min Max
Factory
setting
- - 2524[0]
r2556
CO: LR position setpoint after setpoint smoothing / s_set after interp
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4015
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]
r2557
CO: LR position controller input system deviation / LR_inp sys dev
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
Integer32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4015
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]
r2558
CO: LR position controller output P component / LR_outp P comp
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2000
Dyn. index:
-
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
4015
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......