List Manual (LH14), 01/2016, A5E33842313
341
2 Parameters
2.2 List of parameters
Description:
Sets the time constant for the position setpoint filter (PT1).
Note:
The effective Kv factor (position loop gain) is reduced with the filter. This allows a softer control behavior with
improved tolerance with respect to noise/disturbances.
Applications:
- reduces the pre-control dynamic response.
- jerk limiting.
Description:
Setting to activate and weight the speed pre-control value.
Value = 0 % --> The pre-control is de-activated.
Dependency:
Refer to: p2535, p2536, r2563
Note:
When the axis control loop is optimally set as well as a precisely determined equivalent time constant of the speed
control loop, the pre-control factor is 100%.
Description:
Sets the "fractional" dead time to emulate the timing behavior of the speed control loop.
The selected multiplier refers to the position controller clock cycle (deadtime= p2535 * p0115[4]).
Dependency:
Refer to: p2536
Notice:
When speed pre-control is active (p2534 > 0 %), the following applies:
In addition to the set dead time (p2535), internally two position controller clock cycles are effective.
When speed pre-control is inactive (p2534 = 0 %), the following applies:
No dead time is effective (p2535 and internal).
Note:
Together with p2536, the timing behavior of the closed-loop control loop can be emulated.
Description:
Sets a PT1 filter to emulate the timing behavior of the closed-speed control loop.
Dependency:
Refer to: p2535
Notice:
When speed pre-control is inactive (p2534 = 0 %), the following applies:
If a PT1 filter has been set, it is not effective.
Note:
Together with p2535, the timing behavior of the closed-loop control loop can be emulated.
p2533[0...n]
LR position setpoint filter time constant / s_set_filt T
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
4015
Min Max
Factory
setting
0.00 [ms]
1000.00 [ms]
0.00 [ms]
p2534[0...n]
LR speed pre-control factor / n_prectrl fact
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
4015, 4025
Min Max
Factory
setting
0.00 [%]
200.00 [%]
0.00 [%]
p2535[0...n]
LR speed pre-control balancing filter dead time / n_prectrFlt t_dead
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
4015
Min Max
Factory
setting
0.00 2.00 0.00
p2536[0...n]
LR speed pre-control symmetrizing filter PT1 / n_prectrl filt PT1
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
4015
Min Max
Factory
setting
0.00 [ms]
100.00 [ms]
0.00 [ms]
Содержание SINAMICS G120D CU240D-2 DP
Страница 1: ...s SINAMICS SINAMICS G120D Control Units CU240D 2 CU250D 2 List Manual 01 2016 Edition ...
Страница 2: ......
Страница 954: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G120D 954 List Manual LH14 01 2016 A5E33842313 ...
Страница 978: ...Index SINAMICS G120D 978 List Manual LH14 01 2016 A5E33842313 ...
Страница 979: ......