background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l.           

User Manual   

EnOcean / J1939

 

 

Document code: MN67C66_ENG     Revision 1.000   Page 1 of 30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.000 
English 

 

EnOcean / J1939 - Converter 

 (Order Code:  HD67C66-B2) 

 
 

For Website information:  

www.adfweb.com?Product=HD67C66-B2

  

 

For Price information: 

www.adfweb.com?Price=HD67C66-B2

 

 

 

Benefits and Main Features: 

 

Very easy to configure 

 

Power Supply 18…35V DC and 8…24 V AC 

 

Temperature range: -40°C/+85°C  (-40°F/+185°F) 

For others EnOcean products, see also the following links: 

 

Converter EnOcean to  

www.adfweb.com?Product=HD67C50

      

(Serial) 

www.adfweb.com?Product=HD67C52

      

(Modbus Slave) 

www.adfweb.com?Product=HD67C54

       

(Modbus TCP Slave) 

www.adfweb.com?Product=HD67C56

      

(BACnet Slave) 

www.adfweb.com?Product=HD67C57

       

(CAN) 

www.adfweb.com?Product=HD67C58

      

(CANopen) 

www.adfweb.com?Product=HD67C61

      

(DeviceNet Slave) 

www.adfweb.com?Product=HD67C63

      

(EtherNet/IP Slave) 

www.adfweb.com?Product=HD67C65

      

(IEC61850 Server) 

www.adfweb.com?Product=HD67C67

      

(KNX) 

www.adfweb.com?Product=HD67C70

      

(MQTT) 

www.adfweb.com?Product=HD67C72

      

(NMEA 0183) 

www.adfweb.com?Product=HD67C73

      

(NMEA 2000) 

www.adfweb.com?Product=HD67C75

      

(PROFIBUS Slave) 

www.adfweb.com?Product=HD67C77

      

(PROFINET Slave) 

www.adfweb.com?Product=HD67C79

      

(SNMP Agent) 

 

 
 

Do you need to choose a device? Do you want help? 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Содержание HD67C66

Страница 1: ...uct HD67C50 Serial www adfweb com Product HD67C52 Modbus Slave www adfweb com Product HD67C54 Modbus TCP Slave www adfweb com Product HD67C56 BACnet Slave www adfweb com Product HD67C57 CAN www adfweb com Product HD67C58 CANopen www adfweb com Product HD67C61 DeviceNet Slave www adfweb com Product HD67C63 EtherNet IP Slave www adfweb com Product HD67C65 IEC61850 Server www adfweb com Product HD67C...

Страница 2: ...CAL SUPPORT 30 RETURN POLICY 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adfweb...

Страница 3: ...e can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a potential hazard if they are inappropriat...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EnOcean J1939 Document code MN67C66_ENG Revision 1 000 Page 4 of 30 EXAMPLE OF CONNECTION ...

Страница 5: ...Industrial Electronic Devices ADFweb com S r l User Manual EnOcean J1939 Document code MN67C66_ENG Revision 1 000 Page 5 of 30 CONNECTION SCHEME Figure 1 Connection scheme for HD67C66 B2 ...

Страница 6: ...haracteristics Electrical isolation between EnOcean and Power Supply Mountable on 35mm Rail DIN Wide power supply input range 18 35V DC and 8 24V AC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67C66 software on your PC in order to perform the following Define the parameter of J1939 line Define the parameter of EnOcean line Define J1939 messages in rx and tx Upda...

Страница 7: ...6_ENG Revision 1 000 Page 7 of 30 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V DC Device Consumption W VA HD67C66 B2 3 5 HD67C66 B2 Caution Not reverse the polarity power ...

Страница 8: ...e position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for upload the Project and or Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specifics functions see LEDS section ...

Страница 9: ...een Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 J1939 communication yellow Blinks when a J1939 message is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 EnOcean communication yellow Blinks when EnOcean data is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 4 Error state yellow ON An erro...

Страница 10: ...Ethernet connection must be made using Connector2 of HD67C66 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC is recommended the use of a cross cable ...

Страница 11: ...r terminating the CAN line with a 120Ω resistor it is necessary that the Dip1 of Dip Switch C is at ON position Cable characteristics DC parameter Impedance 70 Ohm m AC parameters Impedance 120 Ohm m Delay 5 ns m Length Baud Rate bps Length MAX m 10 K 5000 20 K 2500 50 K 1000 100 K 650 125 K 500 250 K 250 500 K 100 800 K 50 1000 K 25 ...

Страница 12: ...ering and lighting Each device uses a unique ID for identification and one of the standardized profiles EEPs for data transmission Communication process may be secure or unsecure and may be unidirectional or bidirectional for devices that support Smart Acknowledge operating mode EnOcean is based on wireless communication on 868 3 MHz ASK It is possible to connect up to 100 EnOcean devices to a sin...

Страница 13: ...verter use the available software that runs with Windows called SW67C66 It is downloadable on the site www adfweb com and its operation is described in this document The software works with MS Windows XP Vista Seven 8 10 32 64bit When launching the SW67C66 the window below appears Fig 2 Note It is necessary to have installed Net Framework 4 Figure 2 Main window for SW67C66 ...

Страница 14: ...figuration A device s configuration can also be imported or exported To clone the configurations of a Programmable EnOcean J1939 Converter in order to configure another device in the same manner it is necessary to maintain the folder and all its contents To clone a project in order to obtain a different version of the project it is sufficient to duplicate the project folder with another name and o...

Страница 15: ...language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67C66 check automatically if there are updatings wh...

Страница 16: ...al EnOcean J1939 Document code MN67C66_ENG Revision 1 000 Page 16 of 30 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the tables contained in the different sections of the software ...

Страница 17: ...e data on EnOcean side are set to 0xFF If the field Enable Peer to Peer is checked the gateway will mask the Source Address of the J1939 messages received In the field ID Device J1939 the ID of J1939 side of the converter is defined The means of the fields for Ethernet are In the fields IP Address the IP address for Ethernet side of the converter is defined In the fields SubNet Mask the SubNet Mas...

Страница 18: ...MN67C66_ENG Revision 1 000 Page 18 of 30 Figure 4 EnOcean Access window ENOCEAN ACCESS By Pressing the EnOcean Set Access button from the main window for SW67C66 Fig 2 the window EnOcean Set Access appears Fig 4 This section is used to define the list of the EnOcean devices to read write ...

Страница 19: ...evice is defined In the field Secure Type the type of EnOcean communication is defined In the field Key the key used for encryption of frames in Secure Mode is defined In the field Rolling Code the Rolling Code for the EnOcean communication is defined In the field Rolling Code Algorithm the type of Rolling Code is defined In the field Rolling Code Tx the transmission of the Rolling Code is enabled...

Страница 20: ...are In the field Rorg the type of EnOcean telegram is defined In the field Func the type of EnOcean instance is defined In the field Type the type of event is defined The means of the Variable fields are In the field Case the format of the EnOcean telegram is defined In the field Variable the variable to read write is defined In the field Position the starting byte of the internal array where mapp...

Страница 21: ...the field Dimension the number of byte of the COB from 1 to 8 is defined The field TimeOut is used for put at zero the data into internal array if the J1939 frame arrives with a frequency less than the time expressed in the field If the value in the field is 0 it means that you don t want to use this feature In the field Byte1 insert the byte of the internal array where saving 1st byte of the J193...

Страница 22: ...d Byte6 insert the byte of the internal array where saving 6th byte of the J1939 message In the field Byte7 insert the byte of the internal array where saving 7th byte of the J1939 message In the field Byte8 insert the byte of the internal array where saving 8th byte of the J1939 message In the field Mnemonic a brief description is defined ...

Страница 23: ... or 2 0B 29 bits In the field Dimension the number of byte of the COB from 1 to 8 is defined If the field OnChange is checked the frame is sent when the data from EnOcean change If the field OnCMD is checked the frame is sent when a EnOcean message is received If the field OnTimer is checked the frame is sent cyclically with the delay defined in the field Time expressed in ms In the field Byte1 in...

Страница 24: ...g 5th byte of the J1939 message In the field Byte6 insert the byte of the internal array where taking 6th byte of the J1939 message In the field Byte7 insert the byte of the internal array where taking 7th byte of the J1939 message In the field Byte8 insert the byte of the internal array where taking 8th byte of the J1939 message In the field Mnemonic it is possible to insert a brief description ...

Страница 25: ... cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of Dip Switch A in OFF position Turn ON the device If you know the actual IP address of the device you have to use this procedure Turn ON the Device with the Ethernet cable inserted Insert the actual IP of...

Страница 26: ...ram inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program more than one device using the UDP Update you have to cancel the ARP table every time you connect a new device on Ethernet For do this you have to launch the Command Prompt and write the command arp d Pay ...

Страница 27: ...ndustrial Electronic Devices ADFweb com S r l User Manual EnOcean J1939 Document code MN67C66_ENG Revision 1 000 Page 27 of 30 Figure 11 Mechanical dimensions scheme for HD67C66 B2 MECHANICAL DIMENSIONS ...

Страница 28: ... valid combination of the following HD67C66 B 2 Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67C66 EnOcean J1939 Converter Order Code HD67C66 B2 EnOcean J1939 Converter ACCESSORIES Order Code AC34011 35mm Rail DIN Power Supply 220 240V AC 50 60Hz 12 V DC Order Code AC34012 35mm Rail DIN Power Supply 220 240V AC 50 60Hz 24 V DC ...

Страница 29: ...systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human health which could otherwise be caused ...

Страница 30: ...he following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchange...

Отзывы: