background image

NEware RS-485/RS-232 Converter

(DGP-CONV1)

Instructions

DGPCONV1-EI00

I

NTRODUCTION

The DGP-CONV1 converter is a local interface between the DigiplexNE
(DGP-NE96) control panel and the NEware System Owner Software.
Connected directly between a computer and the DigiplexNE, the DGP-
CONV1 will transfer information at a speed of 19,200 or 38,400 baud to a
distance of up to 1000ft (300m).

O

VERVIEW

The converter comes in two parts, the 

Alarm Panel (AP) Board

 and the

Computer (CPU) Board

 (see Figure 1). The 

AP

 board is installed in the metal

box that houses the control panel while the 

CPU

 board is installed close to

the computer. The boards are then connected together to complete the
interface. Figure 1 shows a general overview of the DGP-CONV1 converter.

H

ARDWARE

 I

NSTALLATION

1. Attach the supplied 4-pin cable to the 4-pin connector on the 

AP

 board

and then insert the other end of the cable into the 4-pin connector labeled

SERIAL

 

PORT

 on the DigiplexNE control panel (see Figure 2). 

2. Connect the 

+12

V

GND

A

+

 and 

B

-

 terminals of the 

AP

 board to the corre-

sponding terminals of the 

CPU

 board as shown in Figure 2. 

3. Insert the phone jack end of the supplied DB-9 cable into the telephone

connector of the 

CPU

 board. Connect the other end of the DB-9 cable into

the desired 

COM

 port of the computer. Refer to Figure 2.

NE

WARE

 S

ETUP

In order to use the DGP-CONV1 it must be setup in the NEware software.
After starting the software, click the 

COM Port

 icon. The 

COM Port

Configuration

 window will appear. Select the COM port to which the

converter is connected to and then select the communication speed (BPS -
baud rate). 

Note: When selecting the baud rate, be sure to select the

same baud rate as set in the DigiplexNE. 

When finished, click 

OK

.

C

ONNECTING

 

THE

 DGP-CONV1 W

ITHIN

 8

M

 (25

FT

.)

If the distance between the between the DigiplexNE and the computer is
within 8m (25ft.), only the 

AP 

board will be required. To connect the DGP-

CONV1 using this method:

1. Attach the 4-pin supplied cable to the 4-pin connector on the 

AP

 board

and then insert the other end of the cable into the 4-pin connector labeled

SERIAL

 

PORT

 on the DigiplexNE control panel (see Figure 3).

2. Insert the phone jack end of the supplied DB-9 cable into the telephone

connector on the 

AP

 board. Connect the other end of the DB-9 cable into

the desired 

COM

 port of the computer. Refer to Figure 3.

 Figure 1: DGP-CONV1 Overview

Отзывы: